126 Poultry House, Cage Operation, Screened, 2 Story Elevated

These two-story structures are elevated off the ground for tractor access cleaning purposes.  They are designed to house hens used for commercial laying.  Costs are averages of various screened and curtain sidewall structures.

Quality is influenced by framing and floor systems (e.g., slab or wood), the amount of interior finish and the lighting and plumbing systems.

The following are related occupancies:

474  Poultry House, Cage Operation, 1 Story

570  Poultry House, Cage Operation, 1 Story Elevated

567  Poultry House, Cage Operation, 2 Story

568  Poultry House, Cage Operation, 2 Story Elevated

569  Poultry House, Cage Operation, 3 Story

115  Poultry House, Cage Operation, Screened, 1 Story

125  Poultry House, Cage Operation, Screened, 1 Story Elevated

116  Poultry House, Cage Operation, Screened, 2 Story

117  Poultry House, Floor Operation, Breeder

118  Poultry House, Floor Operation, Broiler

119  Turkey Barn

Note:  Exterior wall choices are not available for this occupancy.

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 17 and 47.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

--

--

--

--

--

--

15

15

--

Average

--

--

--

--

--

--

20

20

--

Good

--

--

--

--

--

--

25

25

--

Excellent

--

--

--

--

--

--

25

25

--

Quality Selection Guide

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal or lath partial walls or screen on light pole frame.

Open ventilation, unfinished, cheap floor, no insulation.

Minimum lighting and water.

None

Low

Metal, insulated, sidewall open screen, no curtains.

Unfinished, pole frame, concrete or wood floor, insulated ceiling.

Adequate electrical service, water service.

None

Fair

Metal, insulated, sidewall open screen, full curtains.

Unfinished, good floor, insulated ceiling.

Adequate lighting and outlets, water service.

None

Average

Heavy pole frame, curtain sidewalls.

Concrete floors, some partitions.

Good lighting and water

None

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal partial walls or screen on light steel frame.

Open ventilation, unfinished, cheap floor, no insulation.

Minimum lighting and water.

None

Low

Metal, insulated, sidewall open screen, no curtains.

Unfinished, pole frame, concrete or wood floor, insulated ceiling.

Adequate electrical service, water service.

None

Fair

Metal, insulated, sidewall open screen, full curtains.

Unfinished, good floor, insulated ceiling.

Adequate lighting and outlets, water service.

None

Average

Heavy steel frame, curtain sides.

Concrete floors, some partitions.

Good lighting and water.

None