These structures are designed for the breeding and housing of poultry at ground level. Costs are averages for open non-environmental (curtain) and enclosed environmental buildings at the average and above quality levels. These structures will have some partitioned concrete slab floor area for egg collection.
The following are not included in the costs: Racks, cages, incubators and other special equipment.
The following are related occupancies:
474 Poultry House, Cage Operation, 1 Story
570 Poultry House, Cage Operation, 1 Story Elevated
567 Poultry House, Cage Operation, 2 Story
568 Poultry House, Cage Operation, 2 Story Elevated
569 Poultry House, Cage Operation, 3 Story
115 Poultry House, Cage Operation, Screened, 1 Story
125 Poultry House, Cage Operation, Screened, 1 Story Elevated
116 Poultry House, Cage Operation, Screened, 2 Story
126 Poultry House, Cage Operation, Screened, 2 Story Elevated
118 Poultry House, Floor Operation, Broiler
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 17 and 47.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
20 |
|
-- |
-- |
15 |
15 |
-- |
Average |
-- |
-- |
20 |
|
-- |
-- |
15 |
15 |
-- |
Good |
-- |
-- |
25 |
|
-- |
-- |
20 |
20 |
-- |
Excellent |
-- |
-- |
25 |
|
-- |
-- |
20 |
20 |
-- |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Minimum block, shutters or vents, light roof structure, insulation. |
Unfinished, partial floor, some partitions, natural ventilation only. |
Minimum wiring and lighting, water service. |
None |
Good |
Brick or block, good ventilation and fenestration. |
Insulated ceiling, some slab and division of space. |
Adequate lighting and water service. |
None |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Light wood frame, wood siding, shutters or vents, insulated building. |
Unfinished, partial floor, some partitions, natural ventilation only. |
Minimum wiring and lighting, water service. |
None |
Good |
Wood siding or stucco, good ventilation and fenestration. |
Insulated ceiling, plywood interior, some slab floor and subdivision. |
Adequate lighting and water service. |
None |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Metal or plywood partial walls or screen on light pole frame. |
Open ventilation, unfinished, partial floor, no insulation, few partitions. |
Minimum lighting and hose bib. |
None |
Low |
Metal, insulated, sidewall top open screen, no curtains. |
Unfinished, pole frame, partial floor, few partitions, insulated ceiling. |
Minimum services |
None |
Fair |
Metal, insulated, sidewall top open screen, side curtains. |
Unfinished, partial floor, few partitions, insulated ceiling. |
Minimum wiring and lighting, water service. |
None |
Average |
Metal siding on pole frame, shutters or vents, insulation |
Unfinished, partial floor, some partitions, natural ventilation only. |
Minimum wiring and lighting, water service. |
None |
Good |
Pole frame, metal siding, fully insulated, ventilated. |
Insulated ceiling, plywood interior, some slab floor and subdivision. |
Adequate lighting and water service. |
None |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Metal partial walls or screen on light steel frame. |
Open ventilation, unfinished, partial floor, no insulation, few partitions. |
Minimum lighting and hose bib. |
None |
Low |
Metal, insulated, sidewall top open screen, no curtains. |
Unfinished, partial floor, few partitions, insulated ceiling. |
Minimum services |
None |
Fair |
Metal, insulated, sidewall top open screen, side curtains. |
Unfinished, partial floor, few partitions, insulated ceiling. |
Minimum wiring and lighting, water service. |
None |
Average |
Metal siding on steel frame, shutters or vents, insulation. |
Unfinished, partial floor, some partitions, natural ventilation only. |
Minimum wiring and lighting, water service. |
None |
Good |
Steel panels and frame, fully insulated, ventilated. |
Insulated ceiling, plywood interior, some slab and division of space. |
Adequate lighting and water service. |
None |