117 Poultry House, Floor Operation, Breeder

These structures are designed for the breeding and housing of poultry at ground level.  Costs are averages for open non-environmental (curtain) and enclosed environmental buildings at the average and above quality levels.  These structures will have some partitioned concrete slab floor area for egg collection.

The following are not included in the costs: Racks, cages, incubators and other special equipment.

The following are related occupancies:

474  Poultry House, Cage Operation, 1 Story

570  Poultry House, Cage Operation, 1 Story Elevated

567  Poultry House, Cage Operation, 2 Story

568  Poultry House, Cage Operation, 2 Story Elevated

569  Poultry House, Cage Operation, 3 Story

115  Poultry House, Cage Operation, Screened, 1 Story

125  Poultry House, Cage Operation, Screened, 1 Story Elevated

116  Poultry House, Cage Operation, Screened, 2 Story

126  Poultry House, Cage Operation, Screened, 2 Story Elevated

118  Poultry House, Floor Operation, Broiler

119  Turkey Barn

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 17 and 47.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

--

--

20

 

--

--

15

15

--

Average

--

--

20

 

--

--

15

15

--

Good

--

--

25

 

--

--

20

20

--

Excellent

--

--

25

 

--

--

20

20

--

Quality Selection Guide

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Minimum block, shutters or vents, light roof structure, insulation.

Unfinished, partial floor, some partitions, natural ventilation only.

Minimum wiring and lighting, water service.

None

Good

Brick or block, good ventilation and fenestration.

Insulated ceiling, some slab and division of space.

Adequate lighting and water service.

None

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Light wood frame, wood siding, shutters or vents, insulated building.

Unfinished, partial floor, some partitions, natural ventilation only.

Minimum wiring and lighting, water service.

None

Good

Wood siding or stucco, good ventilation and fenestration.

Insulated ceiling, plywood interior, some slab floor and subdivision.

Adequate lighting and water service.

None

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal or plywood partial walls or screen on light pole frame.

Open ventilation, unfinished, partial floor, no insulation, few partitions.

Minimum lighting and hose bib.

None

Low

Metal, insulated, sidewall top open screen, no curtains.

Unfinished, pole frame, partial floor, few partitions, insulated ceiling.

Minimum services

None

Fair

Metal, insulated, sidewall top open screen, side curtains.

Unfinished, partial floor, few partitions, insulated ceiling.

Minimum wiring and lighting, water service.

None

Average

Metal siding on pole frame, shutters or vents, insulation

Unfinished, partial floor, some partitions, natural ventilation only.

Minimum wiring and lighting, water service.

None

Good

Pole frame, metal siding, fully insulated, ventilated.

Insulated ceiling, plywood interior, some slab floor and subdivision.

Adequate lighting and water service.

None

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal partial walls or screen on light steel frame.

Open ventilation, unfinished, partial floor, no insulation, few partitions.

Minimum lighting and hose bib.

None

Low

Metal, insulated, sidewall top open screen, no curtains.

Unfinished, partial floor, few partitions, insulated ceiling.

Minimum services

None

Fair

Metal, insulated, sidewall top open screen, side curtains.

Unfinished, partial floor, few partitions, insulated ceiling.

Minimum wiring and lighting, water service.

None

Average

Metal siding on steel frame, shutters or vents, insulation.

Unfinished, partial floor, some partitions, natural ventilation only.

Minimum wiring and lighting, water service.

None

Good

Steel panels and frame, fully insulated, ventilated.

Insulated ceiling, plywood interior, some slab and division of space.

Adequate lighting and water service.

None