These one-story structures are elevated off the ground for tractor access cleaning purposes. They are designed to house hens used for commercial laying. Costs are averages of various screened and curtain sidewall structures.
Quality is influenced by framing and floor systems (e.g., slab or wood), the amount of interior finish and the lighting and plumbing systems.
The following are related occupancies:
474 Poultry House, Cage Operation, 1 Story
570 Poultry House, Cage Operation, 1 Story Elevated
567 Poultry House, Cage Operation, 2 Story
568 Poultry House, Cage Operation, 2 Story Elevated
569 Poultry House, Cage Operation, 3 Story
115 Poultry House, Cage Operation, Screened, 1 Story
116 Poultry House, Cage Operation, Screened, 2 Story
126 Poultry House, Cage Operation, Screened, 2 Story Elevated
117 Poultry House, Floor Operation, Breeder
118 Poultry House, Floor Operation, Broiler
Note: Exterior wall choices are not available for this occupancy.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 17 and 47.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
-- |
-- |
-- |
-- |
15 |
15 |
-- |
Average |
-- |
-- |
-- |
-- |
-- |
-- |
20 |
20 |
-- |
Good |
-- |
-- |
-- |
-- |
-- |
-- |
25 |
25 |
-- |
Excellent |
-- |
-- |
-- |
-- |
-- |
-- |
25 |
25 |
-- |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Metal or lath partial walls or screen on light pole frame. |
Open ventilation, unfinished, cheap floor, no insulation. |
Minimum lighting and water. |
None |
Low |
Metal, insulated, sidewall open screen, no curtains. |
Unfinished, pole frame, concrete or wood floor, insulated ceiling. |
Adequate electrical service, water service. |
None |
Fair |
Metal, insulated, sidewall open screen, full curtains. |
Unfinished, good floor, insulated ceiling. |
Adequate lighting and outlets, water service. |
None |
Average |
Heavy pole frame, curtain sidewalls. |
Concrete floors, some partitions. |
Good lighting and water. |
None |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Metal partial walls or screen on light steel frame. |
Open ventilation, unfinished, cheap floor, no insulation. |
Minimum lighting and water. |
None |
Low |
Metal, insulated, sidewall open screen, no curtains. |
Unfinished, pole frame, concrete or wood floor, insulated ceiling. |
Adequate electrical service, water service. |
None |
Fair |
Metal, insulated, sidewall open screen, full curtains. |
Unfinished, good floor, insulated ceiling. |
Adequate lighting and outlets, water service. |
None |
Average |
Heavy steel frame, curtain sides. |
Concrete floors, some partitions. |
Good lighting and water. |
None |