110 Hog Farrowing

These structures are designed for the farrowing or birth and nursing cycle of swine production.  The lowest cost buildings have open curtain sidewalls, while the better buildings are totally enclosed environmental structures.  Costs include concrete floors and the subdivision of spaces.  Most have some type of flushing system.

For slotted floors use one of the following:

Finished Basement for Deep Pit

Semi-finished Basement for Shallow Pit

Unfinished Basement for Flush Pit

The following are related occupancies:

109  Hog Breeding

396  Hog Barn

111  Hog Finishing

112  Hog Nursery

430  Hog Shed

429  Hog Shed, Modified

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 17 and 47.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

--

--

20

15

--

--

15

15

--

Average

--

--

30

25

--

--

25

25

--

Good

--

--

35

30

--

--

30

30

--

Excellent

--

--

35

30

--

--

30

30

--

Quality Selection Guide

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Block, side curtains or vents.

Some insulation, slab, subdivided.

Minimum services

None

Average

Brick or block, adequate fenestration, ventilated.

Insulated ceiling, slab floor, subdivided.

Adequate lighting and water service.

None

Good

Brick or block, good ventilation and fenestration.

Insulated, slab floor, subdivided.

Good lighting and water service.

None

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Wood, side curtains or vents.

Some insulation, slab, subdivided.

Minimum services

None

Average

Wood siding or stucco, adequate fenestration, ventilated.

Insulated, slab floor, subdivided.

Adequate lighting, water service.

None

Good

Wood siding or stucco, good ventilation and fenestration.

Insulated, slab floor, subdivided.

Good lighting and water service.

None

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal on pole, natural ventilation.

Slab floor, subdivided.

Minimum services

None

Low

Metal, side curtains or vents.

Some insulation, slab, subdivided.

Minimum services

None

Average

Pole frame, metal siding, insulated, ventilated.

Insulated ceiling, interior sheathing, slab floor, subdivided.

Adequate lighting and water service.

None

Good

Pole frame, metal siding, fully insulated and ventilated.

Insulated ceiling, interior sheathing, slab floor, subdivided.

Good lighting and water service.

None

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal on steel, natural ventilation.

Slab floor, subdivided.

Minimum services

 

Low

Steel, side curtains or vents.

Some insulation, slab, subdivided.

Minimum services

None

Average

Steel panels and frame, insulated, ventilated.

Insulated ceiling, interior sheathing, slab floor, subdivided.

Adequate lighting and water service.

None

Good

Steel panels and frame, fully insulated and ventilated.

Insulated ceiling, interior sheathing, slab floor, subdivided.

Good lighting and water service.

None