These structures are designed for the breeding and gestation cycle of swine production. The low cost building has open sidewall curtains, while the better buildings are a fully enclosed environmental structure. Costs include concrete floors and subdivided spaces. Most have some type of flushing system.
For slotted floors use one of the following:
Finished Basement for Deep Pit
Semi-finished Basement for Shallow Pit
Unfinished Basement for Flush Pit
The following are related occupancies:
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 17 and 47.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
20 |
15 |
-- |
-- |
15 |
15 |
-- |
Average |
-- |
-- |
30 |
25 |
-- |
-- |
25 |
25 |
-- |
Good |
-- |
-- |
35 |
30 |
-- |
-- |
30 |
30 |
-- |
Excellent |
-- |
-- |
35 |
30 |
-- |
-- |
30 |
30 |
-- |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Block or structural tile, side curtains or vents. |
Unfinished, slab floor, some division of space. |
Minimum lighting and water service. |
None |
Average |
Block or structural tile, adequate fenestration, ventilated. |
Insulated ceiling, slab, some division of space. |
Adequate lighting, water service. |
None |
Good |
Brick or block, good ventilation and fenestration. |
Insulated, slab floor, subdivided. |
Good lighting and water service. |
None |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Low-cost boards, natural ventilation. |
Slab floor, some subdivision. |
Minimum services |
None |
Low |
Boards or plywood, on box frame, some insulation, curtains or vents. |
Some wainscot, slab floor, some division of space. |
Minimum lighting and water service. |
None |
Average |
Stucco or wood siding, insulated, ventilated. |
Insulated ceiling, plywood interior, slab floor, some subdivision. |
Adequate lighting, water service. |
None |
Good |
Wood siding or stucco, good ventilation and fenestration. |
Insulated, slab floor, subdivided. |
Good lighting and water service. |
None |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Metal on pole, natural ventilation. |
Slab floor, some subdivision. |
Minimum services |
None |
Low |
Pole frame, metal siding, some insulation, side curtains or vents. |
Some wainscot, slab floor, some division of space. |
Minimum lighting and water service. |
None |
Average |
Pole frame, metal siding, insulated, ventilated. |
Insulated ceiling, plywood interior, slab floor, some subdivision. |
Adequate lighting, water service |
None |
Good |
Pole frame, metal siding, fully insulated, ventilated. |
Insulated ceiling, interior sheathing, slab floor, subdivided. |
Good lighting and water service. |
None |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Metal on steel, natural ventilation. |
Slab floor, some subdivision. |
Minimum services |
None |
Low |
Steel siding and frame, some insulation, side curtains or vents. |
Some wainscot, slab floor, some division of space. |
Minimum lighting and water service. |
None |
Average |
Steel siding and frame, insulated, ventilated. |
Insulated ceiling, plywood interior, slab, some division of space. |
Adequate lighting and water service. |
None |
Good |
Steel panels and frame, fully insulated, ventilated. |
Insulated ceiling, interior sheathing, slab floor, subdivided. |
Good lighting and water service. |
None |