109 Hog Breeding

These structures are designed for the breeding and gestation cycle of swine production.  The low cost building has open sidewall curtains, while the better buildings are a fully enclosed environmental structure.  Costs include concrete floors and subdivided spaces.  Most have some type of flushing system.

For slotted floors use one of the following:

Finished Basement for Deep Pit

Semi-finished Basement for Shallow Pit

Unfinished Basement for Flush Pit

The following are related occupancies:

396  Hog Barn

110  Hog Farrowing

111  Hog Finishing

112  Hog Nursery

430  Hog Shed

429  Hog Shed, Modified

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 17 and 47.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

--

--

20

15

--

--

15

15

--

Average

--

--

30

25

--

--

25

25

--

Good

--

--

35

30

--

--

30

30

--

Excellent

--

--

35

30

--

--

30

30

--

Quality Selection Guide

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Block or structural tile, side curtains or vents.

Unfinished, slab floor, some division of space.

Minimum lighting and water service.

None

Average

Block or structural tile, adequate fenestration, ventilated.

Insulated ceiling, slab, some division of space.

Adequate lighting, water service.

None

Good

Brick or block, good ventilation and fenestration.

Insulated, slab floor, subdivided.

Good lighting and water service.

None

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Low-cost boards, natural ventilation.

Slab floor, some subdivision.

Minimum services

None

Low

Boards or plywood, on box frame, some insulation, curtains or vents.

Some wainscot, slab floor, some division of space.

Minimum lighting and water service.

None

Average

Stucco or wood siding, insulated, ventilated.

Insulated ceiling, plywood interior, slab floor, some subdivision.

Adequate lighting, water service.

None

Good

Wood siding or stucco, good ventilation and fenestration.

Insulated, slab floor, subdivided.

Good lighting and water service.

None

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal on pole, natural ventilation.

Slab floor, some subdivision.

Minimum services

None

Low

Pole frame, metal siding, some insulation, side curtains or vents.

Some wainscot, slab floor, some division of space.

Minimum lighting and water service.

None

Average

Pole frame, metal siding, insulated, ventilated.

Insulated ceiling, plywood interior, slab floor, some subdivision.

Adequate lighting, water service

None

Good

Pole frame, metal siding, fully insulated, ventilated.

Insulated ceiling, interior sheathing, slab floor, subdivided.

Good lighting and water service.

None

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal on steel, natural ventilation.

Slab floor, some subdivision.

Minimum services

None

Low

Steel siding and frame, some insulation, side curtains or vents.

Some wainscot, slab floor, some division of space.

Minimum lighting and water service.

None

Average

Steel siding and frame, insulated, ventilated.

Insulated ceiling, plywood interior, slab, some division of space.

Adequate lighting and water service.

None

Good

Steel panels and frame, fully insulated, ventilated.

Insulated ceiling, interior sheathing, slab floor, subdivided.

Good lighting and water service.

None