This shed has an open front and is used for the farrowing, raising and fattening of swine. Walls are constructed with an exterior covering of vertical boards, plywood or metal siding. The sidewalls are usually stationary. The back wall may be hinged for ventilation. There usually is some electrical and water to the pens. Most have some type of flushing system.
For slotted floors use one of the following:
Finished Basement for Deep Pit
Semi-finished Basement for Shallow Pit
Unfinished Basement for Flush Pit
For this occupancy, which may have one or more open sides, you should always enter the actual walled perimeter. If the shape option is used, the program calculates perimeter based on a three-sided structure.
The following are related occupancies:
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 17 and 47.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
-- |
15 |
15 |
-- |
15 |
15 |
15 |
Average |
-- |
-- |
-- |
20 |
20 |
-- |
20 |
20 |
20 |
Good |
-- |
-- |
-- |
25 |
25 |
-- |
25 |
25 |
25 |
Excellent |
-- |
-- |
-- |
25 |
25 |
-- |
25 |
25 |
25 |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Plywood, open front, vents |
Minimum facility, some flooring |
Hose bibs |
None |
Low |
Vertical boards or plywood, open front, back vents |
Some wainscot, slab floor, some division of space |
Water service |
None |
Average |
Stucco or wood siding, open front, upper doors |
Some ceiling insulation, slab floor, subdivided |
Adequate electrical, water, feed, not automated |
None |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Wood, pipe hoop, fabric cover |
Minimum facility, some flooring |
Hose bibs |
None |
Low |
Wood post, knee wall, pipe hoop frame, fabric cover, end gates |
Some wainscot, partial floor, some division of space |
Minimum water service, feed, not automated |
None |
Average |
Wood post, knee wall, pipe hoop, fabric cover, end walls, curtains |
Concrete slab floor, subdivided |
Adequate electrical, water, feed, not automated |
None |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Metal, open front, vents |
Minimum facility, some flooring |
Hose bibs |
None |
Low |
Pole frame, metal siding, open front, back vents |
Some wainscot, slab floor, some division of space |
Water service |
None |
Average |
Pole frame, metal siding, open front, upper doors |
Some ceiling insulation, slab floor, subdivided |
Adequate electrical, water, feed, not automated |
None |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Steel, open front, vents |
Minimum facility, some flooring |
Hose bibs |
None |
Low |
Steel panels and frame, open front, back vents |
Some wainscot, slab floor, some division of space |
Water service |
None |
Average |
Steel siding and frame, open front, upper doors |
Some ceiling insulation, slab floor, subdivided |
Adequate electrical, water, feed, not automated |
None |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Light steel, open front, vents |
Minimum facility, some flooring |
Hose bibs |
None |
Low |
Steel panels and slant frame, open front, back vents |
Some wainscot, slab floor, some division of space |
Water service |
None |