396 Hog Barn

These barns provide for the breeding, nursery, farrowing and finishing of swine. Costs are averages of the various types that make up a facility. The lower qualities are open curtain-walled, partially floored finishing barns only. There usually is some electrical and water to the pens. Higher quality types have concrete floors and are suitable for Environmental Control Confinement Housing. Most have some type of flushing system.

For slotted floors use one of the following:

Finished Basement for Deep Pit

Semi-finished Basement for Shallow Pit

Unfinished Basement for Flush Pit

The following are related occupancies:

430 Hog Shed

429 Hog Shed, Modified

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 17 and 47.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

--

--

20

15

--

--

15

15

--

Average

--

--

30

25

--

--

25

25

--

Good

--

--

35

30

--

--

30

30

--

Excellent

--

--

35

30

--

--

30

30

--

Quality Selection Guide:

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Cheap block

Unfinished, dirt floor, finishing

Minimum services

None

Low

Block or structural tile, little fenestration

Unfinished, partial floor, some division of space, grow/finish

Minimum lighting and water service

None

Average

Block or structural tile, adequate fenestration

Insulated ceiling, slab, some division of space, gestation

Adequate lighting, water service

None

Good

Brick or block, good ventilation and fenestration

Insulated, slab floor, subdivided, breed/gestation

Good lighting and water service

None

Very Good

Brick or block, good ventilation and fenestration

Insulated, slab floor, subdivided, farrowing

Good lighting and water service

None

Excellent

Brick or block, good ventilation and fenestration

Insulated, slab floor, subdivided, office, nursery

Good lighting & plumbing, lab

None

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Plywood or low cost boards

Unfinished, dirt floor, finishing

Minimum services

None

Low

Vertical boards or plywood, on box frame, some insulation

Some wainscot, partial floor, some division of space, grow/finish

Minimum lighting and water service

None

Average

Stucco or wood siding, insulated

Insulated ceiling, plywood interior, slab floor, some subdivision, gestation

Adequate lighting, water service

None

Good

Wood siding or stucco, good ventilation and fenestration

Insulated, slab floor, subdivided, breed/gestation

Good lighting and water service

None

Very Good

Wood siding or stucco, good ventilation and fenestration

Insulated, slab floor, subdivided, farrowing

Adequate lighting, water service

None

Excellent

Wood siding or stucco, good ventilation and fenestration

Insulated, slab floor, subdivided, office, nursery

Good lighting & plumbing, lab

None

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Pole frame, metal siding

Unfinished, dirt floor, finishing

Minimum services

None

Low

Pole frame, metal siding, some insulation

Some wainscot, partial floor, some division of space, grow/finish

Minimum lighting and water service

None

Average

Pole frame, metal siding, insulated

Insulated ceiling, plywood interior, slab floor, some subdivision, gestation

Adequate lighting, water service

None

Good

Pole frame, metal siding, fully insulated, ventilated

Insulated ceiling, interior sheathing, slab floor, subdivided, breed/gestation

Good lighting and water service

None

Very Good

Pole frame, metal siding, fully insulated, ventilated

Insulated ceiling, interior sheathing, slab floor, subdivided, farrowing

Good lighting and water service

None

Excellent

Pole frame, metal siding, fully insulated, ventilated

Insulated ceiling, interior sheathing, slab floor, subdivided, office, nursery

Good lighting & plumbing, lab

None

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Steel siding and frame, some insulation

Some wainscot, partial floor, some division of space, grow/finish

Minimum lighting and water service

None

Average

Steel siding and frame, insulated

Insulated ceiling, plywood interior, slab, some division of space, gestation

Adequate lighting and water service

None

Good

Steel panels and frame, fully insulated, ventilated

Insulated ceiling, interior sheathing, slab floor, subdivided, breed/gestation

Good lighting and water service

None

Very Good

Steel panels and frame, fully insulated, ventilated

Insulated ceiling, interior sheathing, slab floor, subdivided, farrowing

Good lighting and water service

None

Excellent

Steel panels and frame, fully insulated, ventilated

Insulated ceiling, interior sheathing, slab floor, subdivided, office, nursery

Good lighting & plumbing, lab

None