This shed has a modified open front (i.e., hinged for ventilation) and is used for the farrowing, raising and fattening of swine. Walls are insulated using block, concrete, wood siding, stucco or metal siding as the exterior cover. The back wall may be hinged for ventilation. There usually is some electrical and water to the pens. Most have some type of flushing system.
For slotted floors use one of the following:
Finished Basement for Deep Pit
Semi-finished Basement for Shallow Pit
Unfinished Basement for Flush Pit
The following are related occupancies:
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 17 and 47.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
20 |
15 |
-- |
-- |
15 |
15 |
-- |
Average |
-- |
-- |
25 |
20 |
-- |
-- |
20 |
20 |
-- |
Good |
-- |
-- |
30 |
25 |
-- |
-- |
25 |
25 |
-- |
Excellent |
-- |
-- |
30 |
25 |
-- |
-- |
25 |
25 |
-- |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Block or concrete, insulated, vent doors |
Insulated ceiling, natural ventilation, slab floor, some division of space |
Minimum lighting and water service |
None |
Average |
Block or concrete, insulated vent doors |
Insulated ceiling, slab, subdivided |
Adequate electrical, water, feed, not automated |
None |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Wood siding and frame, insulated, vent doors |
Insulated ceiling, natural ventilation, slab floor, some division of space |
Minimum lighting and water service |
None |
Average |
Wood siding or stucco, insulated vent doors |
Insulated ceiling, interior sheathing, slab floor, subdivided |
Adequate electrical, water, feed, not automated |
None |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Pole frame, metal siding, insulated, vent doors |
Insulated ceiling, natural ventilation, slab floor, some division of space |
Minimum lighting and water service |
None |
Average |
Pole frame, metal siding, insulated vent doors |
Insulated ceiling, interior sheathing, slab floor, subdivided |
Adequate electrical, water, feed, not automated |
None |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Steel panels and frame, insulated, vent doors |
Insulated ceiling, natural ventilation, slab floor, some division of space |
Minimum lighting and water service |
None |
Average |
Steel siding and frame, insulated vent doors |
Insulated ceiling, plywood interior, slab floor, subdivided |
Adequate electrical, water, feed, not automated |
None |