779 Shell, Hotel - Limited Service

This occupancy, together with occupancy 997 (Interior Space, Hotel – Limited Service), allows you to individually price the shell and the tenant improvement costs for an apartment (in separate sections of the report).  This provides an alternative to occupancy 595 (Hotel – Limited Service), which includes both the shell and tenant improvement costs.

These shell structures are three or more stories high, having multiple sleeping units and limited common area amenities.  Limited service hotels include some lounge or recreation support facilities, lobby, laundry, storage and office space commensurate with the size and quality of the facility.  These shell structures include common area finishes only, which are about 5%.  

The following are not included in the costs: Canopies and balconies, swimming pools, furniture, fixtures and equipment (such as kitchen appliances, etc.) that are not permanently attached under the general building contract.

Use occupancy 552 (Recreational Enclosure) for pool enclosure buildings.

Availability of Elevators by Area for this occupancy: Yes

Marshall Valuation Service sections: 11 and 41.

Occupancy Availability: Commercial Estimator only.

Typical Lives:

 

 

 

Class

 

 

Quality

A

B

C

D

S

Low

50

50

45

40

40

Average

50

50

45

40

40

Good

55

55

50

45

45

Excellent

60

60

50

45

45

Quality Selection Guide:

In addition to being an aid in selecting a building’s rank, the following indicates what is included in the base shell cost.  Note that HVAC costs have been included in the total with the finished build-out space in occupancy 997 (Interior Space, Hotel - Limited Service). You can allocate a prorated amount back to the shell cost if needed by selecting the appropriate HVAC component and entering a percentage of the total floor area, typically 15% to 25%.

Class A (Fireproof Structural Steel Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick, concrete block, metal stud panels, little ornamentation

Small lobby, some carpet and tile, typical economy facility

Minimum lighting & plumbing, few core extras

None

Average

Face brick, metal, concrete or EIFS panels, plain exterior

Plaster/drywall and paint, good carpet, support services

Average lighting & plumbing, standard core fixtures

None

Good

Face brick, metal or good concrete or stucco panels

Typical good commercial or motor hotel, core services

Good lighting, and core plumbing fixtures

None

Excellent

Metal or stone, heat-absorbent or double glazing

Fine detail and carpet, good plaster and wall coverings, excellent lobby

Best lighting, and top quality core plumbing

None

Class B (Reinforced Concrete Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick, concrete block, synthetic plaster, little ornamentation

Small lobby, some carpet and tile, typical economy facility

Minimum lighting & plumbing, few core extras

None

Average

Face brick, metal, concrete or EIFS panels, plain exterior

Plaster/drywall and paint, good carpet, support services

Average lighting & plumbing, standard core fixtures

None

Good

Face brick, metal or good concrete or stucco panels

Typical good commercial or motor hotel, core services

Good lighting, and core plumbing fixtures

None

Excellent

Metal or stone, heat-absorbent or double glazing

Fine detail and carpet, good plaster and wall coverings, excellent lobby

Best lighting, and top quality core plumbing

None

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick or concrete block

Small lobby, some carpet and tile, typical economy facility

Minimum lighting & plumbing, few core extras

None

Average

Block or brick, standard front, small lobby, vending area

Plaster/drywall and paint, good carpet, support services

Average lighting & plumbing, guest laundry and small lobby restrooms

None

Good

Brick, metal or concrete and glass, good trim and entrance

Typical good commercial or motor hotel, core services

Good lighting, and core plumbing fixtures

None

Excellent

Metal or concrete panels, stone, brick, individual design

Fine detail and carpet, good plaster and wall coverings, excellent lobby

Best lighting, and top quality core plumbing

None

 

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Stucco or siding, very plain

Small lobby, some carpet and tile, typical economy facility

Minimum lighting & plumbing, few core extras

None

Average

Siding or stucco, standard front, small lobby, vending area

Plaster/drywall and paint, good carpet, support services

Average lighting & plumbing, guest laundry and small lobby restrooms

None

Good

Brick veneer, EIFS, metal and glass, good entrance and trim

Typical good commercial or motor hotel, core services

Good lighting, and core plumbing fixtures

None

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Insulated panels, some ornamentation

Plaster/drywall and paint, good carpet, support services

Average lighting & plumbing, guest laundry and small lobby restrooms

None