552 Recreational Enclosure

These structures are designed to specifically shelter swimming facilities from the elements. The lowest pre-engineered structures are light-residential patio-style enclosures only, while the better qualities are typical of hotel/motel-type facilities with ancillary restrooms, exercise, or lounge finishes commensurate with the quality level.

Pool costs are not included.

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 11 and 41.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

--

--

35

25

--

--

25

20

--

Average

--

--

40

35

--

--

35

35

--

Good

--

--

45

40

--

--

40

40

--

Excellent

--

--

45

40

--

--

40

40

--

Quality Selection Guide:

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Block or tilt-up, light frame, very plain, composition or metal roof

Light slab area, low-cost finishes, add for pool

Minimum lighting, no restrooms

None

Average

Ornamental block, brick, good knee wall or fenestration, shingles

Concrete deck, few partitions, add for pool and spa

Adequate lighting and water service, small restrooms

Space heaters

Good

Face brick or block, good fenestration or good skylights, operable windows

Good flooring, lounge area, add for pool and spa

Good lighting, large tiled restrooms, some extras, sauna

Space heaters

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Stucco or siding, light frame, very plain, composition or metal roof

Light slab area, low-cost finishes, add for pool

Minimum lighting, no restrooms

None

Average

Brick veneer, good siding, good knee wall or fenestration, shingles

Concrete deck, few partitions, add for pool and spa

Adequate lighting and water service, small restrooms

Space heaters

Good

Masonry veneer, good fenestration or good skylights, operable windows

Good flooring, lounge area, add for pool and spa

Good lighting, large tiled restrooms, some extras, sauna

Space heaters

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Post frame, low-cost metal panels, plastic, screens or knee wall

Light slab area, low-cost finishes, add for pool

Minimum lighting, no restrooms

None

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Screen enclosure only, light frame

Some concrete, add for pool

Minimum service

None

Low

Pre-engineered, low-cost panels, plastic, screens or knee wall

Light slab area, low-cost finishes, add for pool

Minimum lighting, no restrooms

None

Average

Good panels, knee wall or good glazing, insulated roof panels

Concrete deck, few partitions, add for pool and spa

Adequate lighting and water service, small restrooms

Space heaters

Good

Sandwich panels, good fenestration or good skylights, operable windows

Good flooring, lounge area, add for pool and spa

Good lighting, large tiled restrooms, some extras, sauna

Space heaters