These structures are designed to specifically shelter swimming facilities from the elements. The lowest pre-engineered structures are light-residential patio-style enclosures only, while the better qualities are typical of hotel/motel-type facilities with ancillary restrooms, exercise, or lounge finishes commensurate with the quality level.
Pool costs are not included.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 11 and 41.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
35 |
25 |
-- |
-- |
25 |
20 |
-- |
Average |
-- |
-- |
40 |
35 |
-- |
-- |
35 |
35 |
-- |
Good |
-- |
-- |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Excellent |
-- |
-- |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Block or tilt-up, light frame, very plain, composition or metal roof |
Light slab area, low-cost finishes, add for pool |
Minimum lighting, no restrooms |
None |
Average |
Ornamental block, brick, good knee wall or fenestration, shingles |
Concrete deck, few partitions, add for pool and spa |
Adequate lighting and water service, small restrooms |
Space heaters |
Good |
Face brick or block, good fenestration or good skylights, operable windows |
Good flooring, lounge area, add for pool and spa |
Good lighting, large tiled restrooms, some extras, sauna |
Space heaters |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Stucco or siding, light frame, very plain, composition or metal roof |
Light slab area, low-cost finishes, add for pool |
Minimum lighting, no restrooms |
None |
Average |
Brick veneer, good siding, good knee wall or fenestration, shingles |
Concrete deck, few partitions, add for pool and spa |
Adequate lighting and water service, small restrooms |
Space heaters |
Good |
Masonry veneer, good fenestration or good skylights, operable windows |
Good flooring, lounge area, add for pool and spa |
Good lighting, large tiled restrooms, some extras, sauna |
Space heaters |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Post frame, low-cost metal panels, plastic, screens or knee wall |
Light slab area, low-cost finishes, add for pool |
Minimum lighting, no restrooms |
None |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Screen enclosure only, light frame |
Some concrete, add for pool |
Minimum service |
None |
Low |
Pre-engineered, low-cost panels, plastic, screens or knee wall |
Light slab area, low-cost finishes, add for pool |
Minimum lighting, no restrooms |
None |
Average |
Good panels, knee wall or good glazing, insulated roof panels |
Concrete deck, few partitions, add for pool and spa |
Adequate lighting and water service, small restrooms |
Space heaters |
Good |
Sandwich panels, good fenestration or good skylights, operable windows |
Good flooring, lounge area, add for pool and spa |
Good lighting, large tiled restrooms, some extras, sauna |
Space heaters |