This occupancy, together with occupancy 779 (Shell, Hotel – Limited Service), allows you to individually price the shell and the tenant improvement costs for a hotel (in separate sections of the report). This provides an alternative to occupancy 595 Hotel, Limited Service, which includes both the shell and tenant improvement costs.
The lower qualities typically have a small lobby – the typical economy facility. The better qualities have fine detail, carpet, good plaster, wall coverings and some custom suites. Some of the special refinements found in the better qualities include television circuits and wet bar.
The following are not included in the costs: Fireplaces, built-in appliances and furnishings.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 11 and 41.
Occupancy Availability: Commercial Estimator only.
|
|
|
Class |
|
|
Quality |
A |
B |
C |
D |
S |
Low |
50 |
50 |
45 |
40 |
40 |
Average |
50 |
50 |
45 |
40 |
40 |
Good |
55 |
55 |
50 |
45 |
45 |
Excellent |
60 |
60 |
50 |
45 |
45 |
In addition to being an aid in selecting a building’s rank, the following indicates what is included in the interior space cost. Note that 100% of the HVAC costs have been included in this occupancy. If you allocated a prorated amount of the HVAC back to the shell cost, you should remove it from this interior space cost by selecting the appropriate HVAC component and entering an appropriate percentage of the total floor area (typically 75% to 85%). For example, if you included 20% of the HVAC cost in the shell, you should enter 80% for the HVAC component in this occupancy.
Class A (Fireproof Structural Steel Frame) and Class B (Reinforced Concrete Frame):
Quality |
Interior Finish |
Lighting & Plumbing |
HVAC |
Low |
Low-cost partitions, paint, vinyl composition, low-cost carpet, one bath per unit |
Minimum lighting & plumbing, few extras |
Individual thru-wall heat pumps |
Average |
Average drywall, vinyl composition, carpet, adequate bedrooms and bath, minimum suites |
Some good suites, lighting & plumbing fixtures, TV circuits |
Heat pump system |
Good |
Plaster or drywall, carpeted, good decorating and detailed rooms, all suites |
Lighting & plumbing above code, standard fixtures, some extras |
Warm and cool air (zoned) |
Excellent |
Good plaster and wall coverings, carpet, fine detailed rooms, some custom suites |
Best lighting, TV circuits, wet bar, top quality plumbing |
Hot and chilled water (zoned) |
Class C (Masonry Bearing Walls), Class D (Wood or Steel Framed Exterior Walls), and Class S (Metal Frame and Walls):
Quality |
Interior Finish |
Lighting & Plumbing |
HVAC |
Low |
Low-cost partitions, paint, vinyl composition, low-cost carpet, one bath per unit |
Minimum lighting & plumbing |
Individual thru-wall heat pumps |
Average |
Average drywall, vinyl composition, carpet, adequate bedrooms and bath, minimum suites |
Adequate lighting and plumbing |
Individual thru-wall heat pumps |
Good |
Plaster or drywall, carpeted, good decorating and detailed rooms, all suites |
Lighting & plumbing above code, standard fixtures, some extras |
Heat pump system |
Excellent |
Good plaster and wall coverings, carpet, fine detailed rooms, some custom suites |
Excellent lighting, radio and TV circuits, quality plumbing |
Warm and cool air (zoned) |