313 Convalescent Hospital

This occupancy includes rest homes, sanitariums, nursing homes and buildings of hospital type construction that give nursing care. They are designed for bed care and/or hotel and nursing care for ambulatory patients. They have treatment and therapy rooms, service and administration areas, nurses' stations and signaling systems commensurate with the building class and quality. These facilities do not have equipment for surgical care and treatment.

Exterior and interior finishes are very similar to hospitals in terms of the materials used. While most have some type of combined heating and cooling system, lower quality units may have heating only.

The following are not included in the costs: Furniture, and equipment such as therapy or kitchen equipment, etc. that are not permanently attached.

The following are related occupancies:

451 Multiple Residence, Senior Citizen (Low Rise), for independent living

589 Multiple Residence, Assisted Living (Low Rise), for assisted living

330 Home for the Elderly, for high-rise assisted living

710 Multiple Residence, Retirement Community Complex

Availability of Elevators by Area for this occupancy: Yes

Marshall Valuation Service sections: 15 and 45.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

45

45

40

35

--

--

35

35

--

Average

45

45

40

35

--

--

35

35

--

Good

50

50

45

40

--

--

40

40

--

Excellent

50

50

45

40

--

--

40

40

--

Quality Selection Guide:

Class A (Fireproof Structural Steel Frame)

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Brick, concrete, metal and glass, little ornamentation

Hospital without surgical facilities, good lounge areas

Signal system, therapy facilities, adequate lighting & plumbing

Hot and chilled water (zoned)

Good

Face brick, stone trim, good metal or concrete with good glazing

Plaster or drywall, vinyl and ceramic walls, carpet and vinyl floors

Signal system, therapy facilities, good lighting & plumbing

Hot and chilled water (zoned)

Class B: Reinforced Concrete Frame

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Brick, concrete, metal and glass, little ornamentation

Hospital without surgical facilities, acoustic and vinyl tile

Signal system, therapy facilities, adequate lighting & plumbing

Hot and chilled water (zoned)

Good

Face brick, stone trim, good metal or concrete with good glazing

Plaster or drywall, vinyl and ceramic walls, carpet and vinyl floors

Signal system, therapy facilities, good lighting & plumbing

Hot and chilled water (zoned)

Class C (Masonry Bearing Walls)

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick, block, tilt-up, little ornamentation, simple entrance

Painted walls, some plaster or drywall, acoustic and asphalt tile

Minimum lighting & plumbing, minimum hospital facilities

Forced air

Average

Brick, block, some metal and glass, some ornamentation

Plaster or drywall, acoustic ceilings, vinyl composition

Signal system, therapy facilities, adequate lighting & plumbing

Package A.C.

Good

Metal and glass, brick, stone trim, some ornamentation

Plaster or drywall, enamel or vinyl walls, vinyl floor, some carpet

Signal system, therapy facilities, good lighting & plumbing

Warm and cool air (zoned)

Excellent

Highly ornamental metal or concrete panels and glass

Plaster, vinyl and ceramic wall finishes, carpet and vinyl floors

Signal system, therapy facilities, good lighting & plumbing

Hot and chilled water (zoned)

Class D (Wood or Steel Framed Exterior Walls)

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Stucco or siding, little trim or ornamentation

Drywall, acoustic and asphalt tile, minimum detail

Adequate lighting & plumbing, minimum extra facilities

Forced air

Average

Good stucco or wood siding with brick or stone trim

Plaster or drywall, acoustic ceilings, vinyl composition

Adequate lighting & plumbing, signal system, some extras

Package A.C.

Good

Brick veneer, EIFS, metal and glass, good entrance and trim

Plaster or drywall, good ceilings and floor covering

Signal system, therapy facilities, good lighting & plumbing

Warm and cool air (zoned)

Excellent

Face brick, stone, metal and glass, highly ornamental

Plaster, vinyl and ceramic wall finishes, carpet and vinyl floors

Signal system, therapy facilities, good lighting & plumbing

Warm and cool air (zoned)

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Pole frame, good metal panels, finished inside, little trim

Drywall, acoustic and asphalt tile, minimum detail

Adequate lighting & plumbing, minimum extra facilities

Forced air

Class S (Metal Frame and Walls)

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Insulated metal panels, little or no ornamentation

Drywall, acoustic and asphalt tile, minimum detail

Adequate lighting & plumbing, minimum extra facilities

Forced air

Average

Sandwich panels with brick or stone trim

Drywall, acoustic ceilings, vinyl composition

Adequate lighting & plumbing, signal system, some extras

Package A.C.