These structures are designed for the care and housing of turkeys at ground level. Costs given are averages for open non-environmental (curtain) buildings with predominantly dirt floors.
The following are related occupancies:
474 Poultry House, Cage Operation, 1 Story
570 Poultry House, Cage Operation, 1 Story Elevated
567 Poultry House, Cage Operation, 2 Story
568 Poultry House, Cage Operation, 2 Story Elevated
569 Poultry House, Cage Operation, 3 Story
115 Poultry House, Cage Operation, Screened, 1 Story
125 Poultry House, Cage Operation, Screened, 1 Story Elevated
116 Poultry House, Cage Operation, Screened, 2 Story
126 Poultry House, Cage Operation, Screened, 2 Story Elevated
117 Poultry House, Floor Operation, Breeder
118 Poultry House, Floor Operation, Broiler
Marshall Valuation Service sections: 17 and 47.
|
|
|
Class |
|
|
Quality |
A |
B |
C |
D |
S |
Low |
-- |
-- |
-- |
15 |
15 |
Average |
-- |
-- |
-- |
15 |
15 |
Good |
-- |
-- |
-- |
20 |
20 |
Excellent |
-- |
-- |
-- |
20 |
20 |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Plywood partial walls, side screen on wood studs, no curtains |
Open ventilation, unfinished, dirt floor, no insulation |
Minimum lighting and hose bib |
None |
Fair |
Siding, insulated, sidewall open screen, side curtains |
Unfinished, dirt floor, some concrete, insulated ceiling |
Adequate services |
None |
Average |
Siding, insulated, sidewall top open screen, curtains and shutters |
Unfinished, partial floor, few partitions, insulated ceiling |
Adequate wiring and lighting, water service |
None |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Wood post, light pipe hoop, fabric cover |
Open ventilation, unfinished, dirt floor, wire fence pens |
Minimum lighting and hose bib |
None |
Average |
Wood post, knee wall, pipe hoop frame, fabric cover, end curtains |
Unfinished, dirt floor, some concrete |
Minimum services |
None |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Metal partial walls, side screen on light pole frame, no curtains |
Open ventilation, unfinished, dirt floor, no insulation |
Minimum lighting and hose bib |
None |
Fair |
Metal, insulated, sidewall open screen, side curtains |
Unfinished, pole frame, dirt floor, some concrete, insulated ceiling |
Adequate services |
None |
Average |
Metal, insulated, sidewall top open screen, curtains and shutters |
Unfinished, partial floor, few partitions, insulated ceiling |
Adequate wiring and lighting, water service |
None |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Metal partial walls, side screen on light steel frame, no curtains |
Open ventilation, unfinished, dirt floor, no insulation |
Minimum lighting and hose bib |
None |
Fair |
Metal, insulated, sidewall open screen, side curtains |
Unfinished, steel frame, dirt floor, some concrete, insulated ceiling |
Adequate services |
None |
Average |
Metal, insulated, sidewall top open screen, curtains and shutters |
Unfinished, partial floor, few partitions, insulated ceiling |
Adequate wiring and lighting, water service |
None |