118 Poultry House, Floor Operation, Broiler

These structures are designed for the raising and housing of poultry at ground level. Costs are averages for open non-environmental (curtain) and enclosed environmental buildings at the average and above quality levels. These structures will have an all dirt floor.

The following are related occupancies:

474 Poultry House, Cage Operation, 1 Story

570 Poultry House, Cage Operation, 1 Story Elevated

567 Poultry House, Cage Operation, 2 Story

568 Poultry House, Cage Operation, 2 Story Elevated

569 Poultry House, Cage Operation, 3 Story

115 Poultry House, Cage Operation, Screened, 1 Story

125 Poultry House, Cage Operation, Screened, 1 Story Elevated

116 Poultry House, Cage Operation, Screened, 2 Story

126 Poultry House, Cage Operation, Screened, 2 Story Elevated

117 Poultry House, Floor Operation, Breeder

119 Turkey Barn

Marshall Valuation Service sections: 17 and 47.

Typical Lives:

 

 

 

Class

 

 

Quality

A

B

C

D

S

Low

--

--

--

--

15

Average

--

--

--

--

15

Good

--

--

--

--

20

Excellent

--

--

--

--

20

Quality Selection Guide:

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal or plywood partial walls or screen on light pole frame

Open ventilation, unfinished, dirt floor, no insulation

Minimum lighting and hose bib

None

Low

Metal, insulated, sidewall top open screen, no curtains

Unfinished, pole frame, dirt floor, insulated ceiling

Minimum services

None

Fair

Metal, insulated, sidewall top open screen, curtain sidewalls

Unfinished, dirt floor, insulated ceiling

Minimum wiring and lighting, water service

None

Average

Pole frame, metal siding insulated, shutters or vents

Insulated ceiling, plywood interior, dirt floor, some subdivision

Adequate lighting and water service

None

Good

Pole frame, metal siding, fully insulated, ventilated

Insulated ceiling, interior sheathing, dirt floor, subdivided

Adequate lighting and water service

None

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal partial walls or screen on light steel frame

Open ventilation, unfinished, dirt floor, no insulation

Minimum lighting and hose bib

None

Low

Metal, insulated, sidewall top open screen, no curtains

Unfinished, steel frame, dirt floor, insulated ceiling

Minimum services

None

Fair

Metal, insulated, sidewall top open screen, curtain sidewalls

Unfinished, dirt floor, insulated ceiling

Minimum wiring and lighting, water service

None

Average

Steel siding and frame, insulated, shutters or vents

Insulated ceiling, plywood interior, dirt, some division of space

Adequate lighting and water service

None

Good

Steel panels and frame, fully insulated, ventilated

Insulated ceiling, interior sheathing, dirt floor, subdivided

Adequate lighting and water service

None