117 Poultry House, Floor Operation, Breeder

These structures are designed for the breeding and housing of poultry at ground level. Costs are averages for open non-environmental (curtain) and enclosed environmental buildings at the average and above quality levels. These structures will have some partitioned concrete slab floor area for egg collection.

The following are related occupancies:

474 Poultry House, Cage Operation, 1 Story

570 Poultry House, Cage Operation, 1 Story Elevated

567 Poultry House, Cage Operation, 2 Story

568 Poultry House, Cage Operation, 2 Story Elevated

569 Poultry House, Cage Operation, 3 Story

115 Poultry House, Cage Operation, Screened, 1 Story

125 Poultry House, Cage Operation, Screened, 1 Story Elevated

116 Poultry House, Cage Operation, Screened, 2 Story

126 Poultry House, Cage Operation, Screened, 2 Story Elevated

118 Poultry House, Floor Operation, Broiler

119 Turkey Barn

Marshall Valuation Service sections: 17 and 47.

Typical Lives:

 

 

 

Class

 

 

Quality

A

B

C

D

S

Low

--

--

20

15

15

Average

--

--

20

15

15

Good

--

--

25

20

20

Excellent

--

--

25

20

20

Quality Selection Guide:

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Minimum block, shutters or vents, light roof structure, insulation

Unfinished, partial floor, some partitions, natural ventilation only

Minimum wiring and lighting, water service

None

Good

Brick or block, good ventilation and fenestration

Insulated ceiling, some slab and division of space

Adequate lighting and water service

None

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Light wood frame, wood siding, shutters or vents, insulated building

Unfinished, partial floor, some partitions, natural ventilation only

Minimum wiring and lighting, water service

None

Good

Wood siding or stucco, good ventilation and fenestration

Insulated ceiling, plywood interior, some slab floor and subdivision

Adequate lighting and water service

None

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal or plywood partial walls or screen on light pole frame

Open ventilation, unfinished, partial floor, no insulation, few partitions

Minimum lighting and hose bib

None

Low

Metal, insulated, sidewall top open screen, no curtains

Unfinished, pole frame, partial floor, few partitions, insulated ceiling

Minimum services

None

Fair

Metal, insulated, sidewall top open screen, side curtains

Unfinished, partial floor, few partitions, insulated ceiling

Minimum wiring and lighting, water service

None

Average

Metal siding on pole frame, shutters or vents, insulation

Unfinished, partial floor, some partitions, natural ventilation only

Minimum wiring and lighting, water service

None

Good

Pole frame, metal siding, fully insulated, ventilated

Insulated ceiling, plywood interior, some slab floor and subdivision

Adequate lighting and water service

None

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Metal partial walls or screen on light steel frame

Open ventilation, unfinished, partial floor, no insulation, few partitions

Minimum lighting and hose bib

None

Low

Metal, insulated, sidewall top open screen, no curtains

Unfinished, partial floor, few partitions, insulated ceiling

Minimum services

None

Fair

Metal, insulated, sidewall top open screen, side curtains

Unfinished, partial floor, few partitions, insulated ceiling

Minimum wiring and lighting, water service

None

Average

Metal siding on steel frame, shutters or vents, insulation

Unfinished, partial floor, some partitions, natural ventilation only

Minimum wiring and lighting, water service

None

Good

Steel panels and frame, fully insulated, ventilated

Insulated ceiling, plywood interior, some slab and division of space

Adequate lighting and water service

None