778 Shell, Hotel - Full Service

This occupancy, together with occupancy 996 (Interior Space, Hotel-Full Service), allows you to individually price the shell and the tenant improvement costs for an apartment (in separate sections of the report).  This provides an alternative to occupancy 594 (Hotel-Full Service), which includes both the shell and tenant improvement costs.

These shell structures are three or more stories high, having multiple sleeping units without individual kitchen facilities.  Where the ground floor is entirely divided into stores and shops, use occupancy 353 (Retail Store) for that floor.  The size of the support facilities, e.g., restaurants, bars, meeting space, etc., is largely dependent on the size and capacity of the facility rather than the quality of the improvements.  Lobby, lounges, restaurants, ballrooms, meeting rooms, kitchens, laundry, storage facilities and office areas are commensurate with the building class and quality chosen.  These shell structures include common area finishes only, which are about 10%.   

The following are not included in the costs: Canopies and balconies, swimming pools, furniture, fixtures and equipment (such as bars, counters or seating, kitchen equipment, etc.) that are not permanently attached under the general building contract.

Use occupancy 552 (Recreational Enclosure) for pool enclosure buildings.

Availability of Elevators by Area for this occupancy: Yes

Marshall Valuation Service sections: 11 and 41.

Occupancy Availability: Commercial Estimator only.

Typical Lives:

 

 

 

Class

 

 

Quality

A

B

C

D

S

Low

50

50

45

40

--

Average

55

55

50

45

--

Good

60

60

50

45

--

Excellent

60

60

50

45

--

Quality Selection Guide:

In addition to being an aid in selecting a building’s rank, the following indicates what is included in the base shell cost.  Note that HVAC costs have been included in the total with the finished build-out space in occupancy 996 (Interior Space, Hotel - Full Service). You can allocate a prorated amount back to the shell cost if needed by selecting the appropriate HVAC component and entering a percentage of the total floor area, typically 15% to 25%.

Class A (Fireproof Structural Steel Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick, concrete block, metal stud panels, little ornamentation

Small lobby, coffee shop, minimum transient facilities

Minimum lighting & plumbing, few core extras

None

Average

Face brick, metal, concrete or stucco panels, plain exterior

Typical good transient or average business hotel, adequate lobby

Average lighting & plumbing, standard core fixtures

None

Good

Face brick, metal or concrete panels, individual design

Good detail, carpeted, highly decorated lobby

Best lighting, and top quality core plumbing

None

Excellent

Best metal or stone, heat-absorbent or double glazing

Good plaster, carpet, wall coverings, fine detailed lobby

Best lighting, and top quality core plumbing

None

Class B (Reinforced Concrete Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick, concrete block, synthetic plaster, little ornamentation

Small lobby, coffee shop, minimum transient facilities

Minimum lighting & plumbing, few core extras

None

Average

Face brick, metal, concrete or stucco panels, plain exterior

Typical good transient or average business hotel, adequate lobby

Average lighting & plumbing, standard core fixtures

None

Good

Face brick, metal or concrete panels, individual design

Good detail, carpeted, highly decorated lobby

Good lighting, and core plumbing fixtures

None

Excellent

Best metal or stone, heat-absorbent or double glazing

Good plaster, carpet, wall coverings, fine detailed lobby

Best lighting, and top quality core plumbing

None

Class C (Masonry Bearing Walls):  

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick or concrete block

Small lobby, coffee shop, minimum transient facilities

Minimum lighting & plumbing, few core extras

None

Average

Brick, stucco on block, some front ornamentation

Typical good transient or average business hotel, adequate lobby

Average lighting & plumbing, standard core fixtures

None

Good

Brick, metal or concrete and glass, good trim and entrance

Good detail, carpeted, highly decorated lobby

Good lighting, and core plumbing fixtures

None

Excellent

Best metal or concrete panels, stone, face brick

Good plaster, carpet, wall coverings, fine detailed lobby

Best lighting, and top quality core plumbing

None

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Stucco or siding

Small lobby, coffee shop, minimum transient facilities

Minimum lighting & plumbing, few core extras

None

Average

Stucco or siding, brick trim, some front ornamentation

Typical good transient or average business hotel, adequate lobby

Average lighting & plumbing, standard core fixtures

None

Good

Brick veneer, metal and glass, good entrance and trim

Good detail, carpeted, highly decorated lobby

Good lighting, and core plumbing fixtures

None

Excellent

Best masonry veneer, metal and glass panels, highly decorative

Good plaster, carpet, wall coverings, fine detailed lobby

Best lighting, and top quality core plumbing

None