These structures are complete stations, including design fees. The building includes an area for office, storage, sales, restroom, and lube areas for service bay stations. Costs include base electric and interior circuits; exterior circuits must be added.
For canopies, use fair to average quality for occupancy 508 (Car Wash Canopy).
For prefabricated food booths, use occupancy 465 (Food Booth, Prefabricated).
For drive-thru car wash, use occupancy 435 (Car Wash, Drive-Thru).
The following are not included in the costs: Hoists and compressors, car wash equipment, food service and display fixtures, and all exterior canopies, equipment and improvements.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service section: 64.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
20 |
15 |
-- |
-- |
-- |
15 |
-- |
Average |
-- |
-- |
20 |
20 |
-- |
-- |
-- |
20 |
-- |
Good |
-- |
-- |
25 |
20 |
-- |
-- |
-- |
20 |
-- |
Excellent |
-- |
-- |
25 |
25 |
-- |
-- |
-- |
25 |
-- |
Class C (Masonry Bearing Walls) and Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Painted steel, inexpensive sash and doors or gates |
Older station, minimum finishes, few built-in items |
Four residential-type fixtures, minimum interior electrical |
Space heaters |
Average |
Average painted steel or block, little trim, small overhangs |
Present-day station, small office, storage, restrooms |
Five to six low-cost commercial plumbing fixtures, standard electrical |
Space heaters |
Good |
Good steel or brick, sectional doors, good sash, large overhangs |
Ranch or suburban style, tiled restrooms, good office |
Average commercial fixtures, adequate interior circuits |
Space heaters |
Excellent |
Best steel or brick, masonry trim, good fenestration, garage doors |
Good finish, best workmanship, many built-in features, tire racks, etc. |
Six to eight good commercial plumbing fixtures, good electrical |
Package AC |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Low-cost siding or stucco, cheap sash and gates |
Substandard, older station, minimal finishes |
Two cheap plumbing fixtures, minimum incandescent lighting |
None |
Low |
Siding or stucco, inexpensive sash and doors or gates |
Older station, minimum finishes, few built-in items |
Two to three low-cost fixtures, minimum interior circuits |
Space heaters |
Average |
Siding or metal on wood frame, little trim, small overhangs |
Present-day station, small office, storage, restrooms |
Five to six low-cost commercial plumbing fixtures, standard electrical |
Space heaters |
Good |
Good sidings, sectional doors, good sash, large overhangs |
Ranch or suburban style, tiled restroom, good office |
Average commercial fixtures, adequate interior circuits |
Space heaters |