408 Service Station

These structures are complete stations, including design fees. The building includes an area for office, storage, sales, restroom, and lube areas for service bay stations. Costs include base electric and interior circuits; exterior circuits must be added.

For canopies, use fair to average quality for occupancy 508 (Car Wash Canopy).

For prefabricated food booths, use occupancy 465 (Food Booth, Prefabricated).

For drive-thru car wash, use occupancy 435 (Car Wash, Drive-Thru).

The following are not included in the costs: Hoists and compressors, car wash equipment, food service and display fixtures, and all exterior canopies, equipment and improvements.

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service section: 64.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

--

--

20

15

--

--

--

15

--

Average

--

--

20

20

--

--

--

20

--

Good

--

--

25

20

--

--

--

20

--

Excellent

--

--

25

25

--

--

--

25

--

Quality Selection Guide:

Class C (Masonry Bearing Walls) and Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Painted steel, inexpensive sash and doors or gates

Older station, minimum finishes, few built-in items

Four residential-type fixtures, minimum interior electrical

Space heaters

Average

Average painted steel or block, little trim, small overhangs

Present-day station, small office, storage, restrooms

Five to six low-cost commercial plumbing fixtures, standard electrical

Space heaters

Good

Good steel or brick, sectional doors, good sash, large overhangs

Ranch or suburban style, tiled restrooms, good office

Average commercial fixtures, adequate interior circuits

Space heaters

Excellent

Best steel or brick, masonry trim, good fenestration, garage doors

Good finish, best workmanship, many built-in features, tire racks, etc.

Six to eight good commercial plumbing fixtures, good electrical

Package AC

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Low-cost siding or stucco, cheap sash and gates

Substandard, older station, minimal finishes

Two cheap plumbing fixtures, minimum incandescent lighting

None

Low

Siding or stucco, inexpensive sash and doors or gates

Older station, minimum finishes, few built-in items

Two to three low-cost fixtures, minimum interior circuits

Space heaters

Average

Siding or metal on wood frame, little trim, small overhangs

Present-day station, small office, storage, restrooms

Five to six low-cost commercial plumbing fixtures, standard electrical

Space heaters

Good

Good sidings, sectional doors, good sash, large overhangs

Ranch or suburban style, tiled restroom, good office

Average commercial fixtures, adequate interior circuits

Space heaters