182 Calving Barn Shed

These sheds are designed as a birthing, newborn creep and sick animal shelter.  They are an open front shed with wood or metal siding attached to wood posts or a steel frame, and a dirt floor.  The walls have rub boards, calving and creep pens and a concrete floored supply/work room and feed storage area at the better qualities.  Costs include minimal electrical and plumbing, feeders and water are not automated.

For this occupancy, which may have one or more open sides, you should always enter the actual walled perimeter.  If the shape option is used, the program calculates perimeter based on a three-sided structure.

The following are not included in the costs: Heat lamps or other special equipment.

The following are related occupancies:

112  Hog Nursery

430  Hog Shed

120  Sheep Shed

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 17 and 47.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

--

--

--

15

15

--

15

15

--

Average

--

--

--

15

15

--

15

15

--

Good

--

--

--

20

15

--

20

20

--

Excellent

--

--

--

20

20

--

20

20

--

Quality Selection Guide:

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Open one side, boards or siding, post/box frame.

Minimum facility, some storage flooring, some subdivision.

Minimum lighting, outlets, and water service.

None

Average

Open one side, boards or siding on wood frame.

Some wainscot, slab floor, supply room, some division of space.

Adequate electrical, water, feed, not automated.

None

Good

Open one side, box frame and siding, some rear vents.

Some ceiling insulation, supply-office, slab floor, subdivided.

Good electrical, water, feed, not automated

None

Class H (Hoop Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Wood post, knee wall, pipe hoop, fabric cover, end gates.

Some wainscot, partial floor, some division of space.

Minimum lighting, outlets, and water service.

None

Average

Wood post, knee wall, pipe hoop, fabric cover, end walls, curtains.

Concrete slab floor, supply area, subdivided pens.

Adequate electrical, water, feed, not automated.

None

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Open one side, metal on pole frame.

Minimum facility, some storage flooring, some subdivision.

Minimum lighting, outlets, and water service

None

Average

Open one side, metal siding on pole frame.

Some wainscot, slab floor, supply room, some division of space.

Adequate electrical, water, feed, not automated.

None

Good

Open one side, metal on pole frame, some rear vents.

Some ceiling insulation, supply-office, slab floor, subdivided.

Good electrical, water, feed, not automated.

None