These sheds are designed as a birthing, newborn creep and sick animal shelter. They are an open front shed with wood or metal siding attached to wood posts or a steel frame, and a dirt floor. The walls have rub boards, calving and creep pens and a concrete floored supply/work room and feed storage area at the better qualities. Costs include minimal electrical and plumbing, feeders and water are not automated.
For this occupancy, which may have one or more open sides, you should always enter the actual walled perimeter. If the shape option is used, the program calculates perimeter based on a three-sided structure.
The following are not included in the costs: Heat lamps or other special equipment.
The following are related occupancies:
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 17 and 47.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
-- |
15 |
15 |
-- |
15 |
15 |
-- |
Average |
-- |
-- |
-- |
15 |
15 |
-- |
15 |
15 |
-- |
Good |
-- |
-- |
-- |
20 |
15 |
-- |
20 |
20 |
-- |
Excellent |
-- |
-- |
-- |
20 |
20 |
-- |
20 |
20 |
-- |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Open one side, boards or siding, post/box frame. |
Minimum facility, some storage flooring, some subdivision. |
Minimum lighting, outlets, and water service. |
None |
Average |
Open one side, boards or siding on wood frame. |
Some wainscot, slab floor, supply room, some division of space. |
Adequate electrical, water, feed, not automated. |
None |
Good |
Open one side, box frame and siding, some rear vents. |
Some ceiling insulation, supply-office, slab floor, subdivided. |
Good electrical, water, feed, not automated |
None |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Wood post, knee wall, pipe hoop, fabric cover, end gates. |
Some wainscot, partial floor, some division of space. |
Minimum lighting, outlets, and water service. |
None |
Average |
Wood post, knee wall, pipe hoop, fabric cover, end walls, curtains. |
Concrete slab floor, supply area, subdivided pens. |
Adequate electrical, water, feed, not automated. |
None |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Open one side, metal on pole frame. |
Minimum facility, some storage flooring, some subdivision. |
Minimum lighting, outlets, and water service |
None |
Average |
Open one side, metal siding on pole frame. |
Some wainscot, slab floor, supply room, some division of space. |
Adequate electrical, water, feed, not automated. |
None |
Good |
Open one side, metal on pole frame, some rear vents. |
Some ceiling insulation, supply-office, slab floor, subdivided. |
Good electrical, water, feed, not automated. |
None |