These relocatable buildings are designed as office structures, typically found in school facilities, and are generally smaller and utilitarian in scope. The lower qualities are generally composed of light mobile/modular structures with minimal finishes. The better qualities will have good modular frames with well-finished walls and floors, good acoustical ceilings, good lighting, cabling, and plumbing fixtures.
The following are not included in the costs: Exterior ramps, landings or steps.
Note: Exterior wall choices are not available for this occupancy.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 18 and 48.
| 
 
  | 
 
  | 
 
  | 
 
  | 
 
  | 
 Class  | 
 
  | 
 
  | 
 
  | 
 
  | 
| 
 Quality  | 
 A  | 
 B  | 
 C  | 
 D  | 
 H  | 
 M  | 
 P  | 
 S  | 
 W  | 
| 
 Low  | 
 --  | 
 --  | 
 --  | 
 20  | 
 --  | 
 --  | 
 --  | 
 --  | 
 --  | 
| 
 Average  | 
 --  | 
 --  | 
 --  | 
 25  | 
 --  | 
 --  | 
 --  | 
 --  | 
 --  | 
| 
 Good  | 
 --  | 
 --  | 
 --  | 
 30  | 
 --  | 
 --  | 
 --  | 
 --  | 
 --  | 
| 
 Excellent  | 
 --  | 
 --  | 
 --  | 
 35  | 
 --  | 
 --  | 
 --  | 
 --  | 
 --  | 
Class D (Wood or Steel Framed Exterior Walls):
| 
 Quality  | 
 Exterior Walls  | 
 Interior Finish  | 
 Mechanicals  | 
 HVAC  | 
| 
 Lowest  | 
 Metal siding on light studs, mobile structure  | 
 Low-cost paneling or drywall, vinyl composition, few partitions  | 
 Minimum electrical to code, few plumbing fixtures  | 
 Individual thru-wall heat pumps  | 
| 
 Low  | 
 Low-cost siding on studs, metal roof  | 
 Drywall partitions, paint, acoustic tile, vinyl composition tile  | 
 Minimum office lighting, cabling and plumbing  | 
 Individual thru-wall heat pumps  | 
| 
 Average  | 
 Standard siding and fenestration, little trim  | 
 Drywall, acoustic tile, carpet and vinyl composition  | 
 Adequate lighting and outlets, plumbing and signal system  | 
 Individual thru-wall heat pumps  | 
| 
 Good  | 
 Siding or stucco, some trim, modular structure  | 
 Drywall, vinyl wall covering, acoustic tile, carpet and vinyl  | 
 Good lighting and outlets, good signal systems and restrooms  | 
 Package A.C.  | 
| 
 Excellent  | 
 Good siding or stucco panels on good modular frame  | 
 Drywall, good vinyl and paneling, good flooring, many private offices  | 
 Good lighting, cabling, many outlets and plumbing, some extras  | 
 Heat pump system  |