585 Mechanical Penthouse

Mechanical penthouses shelter the building’s elevator and other mechanical equipment that is generally located on the roof. The excellent quality represents a full intermediate mechanical-utility floor found in large high-rise construction. For finished penthouses, i.e., those containing roof apartments, restaurants, use the proper costs for that occupancy.

Note: Exterior wall choices are not available for this occupancy.

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 15 and 45.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

50

50

45

40

--

--

--

40

--

Average

55

55

50

45

--

--

--

45

--

Good

60

60

55

50

--

--

--

50

--

Excellent

60

60

55

50

--

--

--

50

--

Quality Selection Guide:

Class A (Fireproof Structural Steel Frame) and Class B (Reinforced Concrete Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Low-cost panels, masonry, very plain

Unfinished interior, roof access only

Minimum lighting, floor drains

None

Average

Curtain panels or masonry, steel roof deck

Unfinished equipment and storage, few partitions

Exposed lighting, adequate drains

None

Good

Good curtain panels, masonry, louvers, concrete roof

Mechanical and storage, some finish and partitions

Adequate lighting, utility outlets and drains

None

Excellent

Louvers, best curtain wall panels, matching spandrel

Intermediate full mechanical floor, utility space, some storage

Adequate lighting, utility outlets and drains

None

Class C (Masonry Bearing Walls), Class D (Wood or Steel Framed Exterior Walls) and Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Light frame or stud single wall, low-cost metal, stucco or siding

Unfinished interior

Minimum lighting, floor drains

None

Average

Frame or bearing walls, good panels, louvers or masonry, trim

Unfinished equipment and storage, few partitions

Exposed lighting, adequate drains

None