These buildings are designed mainly for coin-operated game entertainment, while better qualities will include limited food service and lounges typically found at fun centers, miniature golf complexes, etc.
The following are not included in the costs: Display or food service equipment.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 16 and 46.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
35 |
30 |
-- |
-- |
30 |
30 |
-- |
Average |
-- |
-- |
40 |
35 |
-- |
-- |
35 |
35 |
-- |
Good |
-- |
-- |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Excellent |
-- |
-- |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Block, tilt-up, light roof construction |
Low-cost finishes, few partitions |
Minimum lighting & plumbing |
Forced air |
Average |
Steel or wood frame or bearing walls, brick, block or tilt-up |
Painted walls, VCT, carpet, large eating or game rooms |
Adequate lighting, outlets and plumbing, snack bar |
Package A.C. |
Good |
Steel frame, good brick, block or tilt-up, tapered girders, good trim |
Acoustic treatment, some theme finishes and extra facilities and rooms |
Good game lighting, sound, restrooms, limited food service |
Heat pump system |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Stucco or siding on studs |
Low-cost finishes, few partitions |
Minimum lighting & plumbing |
Forced air |
Average |
Stucco on wood frame, wood trusses, small front |
Drywall, acoustic tile, VCT, carpet, large eating area and game rooms |
Adequate lighting, outlets and plumbing, snack bar |
Package A.C. |
Good |
Heavy wood frame, wood, stucco or brick veneer, good ornamentation |
Acoustic treatment, some theme finishes and extra facilities and rooms |
Good game lighting, sound, restrooms, limited food service |
Heat pump system |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Pole frame, metal siding |
Low-cost game area, minimum finish, asphalt tile, open counter |
Minimum lighting & plumbing, adequate outlets |
Forced air |
Average |
Pole frame, good metal siding, insulated, small front |
Drywall, acoustic tile, VCT, carpet, large eating area and game rooms |
Adequate lighting, outlets and plumbing, snack bar |
Package A.C. |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Steel or aluminum panels |
Drywall, acoustic and asphalt tile |
Minimum lighting & plumbing |
Forced air |
Average |
Good metal panels and roof, little ornamentation, small front |
Drywall, acoustic tile, VCT, carpet, large eating area and game rooms |
Adequate lighting, outlets and plumbing, small snack bar |
Package A.C. |