These are passenger or commuter terminal buildings, from low-quality bus or train stop waiting structures to high-cost major airport-type facilities with separate baggage, ticket lobby, concession, lounge and concourse facilities.
The following are not included in the costs: Ticket, baggage, boarding, concession or other food service equipment.
Availability of Elevators by Area for this occupancy: Yes
Marshall Valuation Service sections: 14 and 44.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
35 |
35 |
30 |
30 |
-- |
-- |
30 |
30 |
-- |
Average |
40 |
40 |
35 |
35 |
-- |
-- |
35 |
35 |
-- |
Good |
40 |
40 |
35 |
35 |
-- |
-- |
35 |
35 |
-- |
Excellent |
45 |
45 |
40 |
40 |
-- |
-- |
40 |
40 |
-- |
Class A (Fireproof Structural Steel Frame): and Class B (Reinforced Concrete Frame):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Brick, precast concrete, good block, some trim |
Finished interior, suspended ceiling, terrazzo lobby, small main terminal |
Average lighting, good sound and plumbing, lounge |
Complete HVAC. |
Average |
Brick, concrete or metal panels, formed concrete, decorative lobby |
Vaulted ceilings, pavers, terrazzo, good air- or train-type terminal |
Good lighting, sound systems and plumbing, food service |
Complete HVAC. |
Good |
Face brick, metal and glass, limestone, architectural concrete |
Good finishes throughout, some extras, typical major terminal facility |
Special lighting, good sound systems and plumbing, some extras |
Complete HVAC. |
Excellent |
Special architecture, metal and glass, stone, concrete, skylights |
Special finishes, acoustic design, high-cost lobby, concourse finishes |
High-quality specialty lighting, best wiring throughout, good plumbing |
Complete HVAC. |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Low-cost block, tilt-up, very plain, acoustic sound walls |
Few partitions, very plain, minimum waiting and concession/ticket area |
Minimum code, public address system |
Package A.C. |
Fair |
Brick, block, concrete panels, plain commercial building, small entry |
Drywall, acoustic tile, vinyl composition lobby, small city bus station |
Minimum lighting, adequate sound, minimum plumbing |
Heat pump system |
Average |
Brick, block, concrete, good front and lobby, some trim |
Finished interior, suspended ceiling, terrazzo lobby, small main terminal |
Average lighting, good sound and plumbing, lounge |
Warm and cool air (zoned) |
Good |
Brick, block, concrete, good decorative front and lobby |
Vaulted ceilings, pavers, terrazzo, good air- or train-type terminal |
Good lighting, sound systems and plumbing, food service |
Hot and chilled water (zoned) |
Very Good |
Face brick, stone, terra cotta, ornamental entrance and lobby |
Good finishes throughout, some extras, typical major terminal facility |
Special lighting, good sound systems and plumbing, some extras |
Complete HVAC. |
Excellent |
High-cost roof, large arched entries and domed skylights |
Special finishes, acoustic design, high-cost lobby, concourse finishes |
High-quality specialty lighting, best wiring throughout, good plumbing |
Complete HVAC. |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Low-cost wood or stucco, very plain |
Few partitions, very plain, minimum waiting and concession/ticket area |
Minimum code, public address system |
Package A.C. |
Fair |
Siding or stucco, small entrance |
Drywall, acoustic tile, vinyl composition lobby, small city bus station |
Minimum lighting, adequate sound, minimum plumbing |
Heat pump system |
Average |
Stucco or siding, good front and lobby, some trim |
Finished interior, suspended ceiling, terrazzo lobby, small main terminal |
Average lighting, good sound and plumbing, lounge |
Warm and cool air (zoned) |
Good |
Stucco, some brick or stone trim, decorative front and lobby |
Vaulted ceilings, pavers, terrazzo, good air-or train-type terminal |
Good lighting, sound systems and plumbing, food service |
Hot and chilled water (zoned) |
Very Good |
Face brick or stone veneer, ornamental entrance and lobby |
Good finishes throughout, some extras, typical major terminal facility |
Special lighting, good sound systems and plumbing, some extras |
Complete HVAC. |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Pole frame and truss, metal siding, low-cost finish and insulation |
Few partitions, very plain, minimum waiting and concession/ticket area |
Minimum code, public address system |
Package A.C. |
Fair |
Metal panels on pole frame, finished interior, small entrance |
Drywall, acoustic tile, vinyl composition lobby, small city bus station |
Minimum lighting, adequate sound, minimum plumbing |
Heat pump system |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Single wall, low-cost interior finish and insulation |
Few partitions, very plain, minimum waiting and concession/ticket area |
Minimum code, public address system |
Package A.C. |
Fair |
Metal panels, finished interior, small entrance, masonry sound walls |
Drywall, acoustic tile, vinyl composition lobby, small city bus station |
Minimum lighting, adequate sound, minimum plumbing |
Heat pump system |
Average |
Good metal panels, roof, front and lobby, some trim |
Finished interior, suspended ceiling, terrazzo lobby, small main terminal |
Average lighting, good sound and plumbing, lounge |
Warm and cool air (zoned) |