571 Passenger Terminal

These are passenger or commuter terminal buildings, from low-quality bus or train stop waiting structures to high-cost major airport-type facilities with separate baggage, ticket lobby, concession, lounge and concourse facilities.

The following are not included in the costs: Ticket, baggage, boarding, concession or other food service equipment.

Availability of Elevators by Area for this occupancy: Yes

Marshall Valuation Service sections: 14 and 44.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

35

35

30

30

--

--

30

30

--

Average

40

40

35

35

--

--

35

35

--

Good

40

40

35

35

--

--

35

35

--

Excellent

45

45

40

40

--

--

40

40

--

Quality Selection Guide:

Class A (Fireproof Structural Steel Frame): and Class B (Reinforced Concrete Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick, precast concrete, good block, some trim

Finished interior, suspended ceiling, terrazzo lobby, small main terminal

Average lighting, good sound and plumbing, lounge

Complete HVAC.

Average

Brick, concrete or metal panels, formed concrete, decorative lobby

Vaulted ceilings, pavers, terrazzo, good air- or train-type terminal

Good lighting, sound systems and plumbing, food service

Complete HVAC.

Good

Face brick, metal and glass, limestone, architectural concrete

Good finishes throughout, some extras, typical major terminal facility

Special lighting, good sound systems and plumbing, some extras

Complete HVAC.

Excellent

Special architecture, metal and glass, stone, concrete, skylights

Special finishes, acoustic design, high-cost lobby, concourse finishes

High-quality specialty lighting, best wiring throughout, good plumbing

Complete HVAC.

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Low-cost block, tilt-up, very plain, acoustic sound walls

Few partitions, very plain, minimum waiting and concession/ticket area

Minimum code, public address system

Package A.C.

Fair

Brick, block, concrete panels, plain commercial building, small entry

Drywall, acoustic tile, vinyl composition lobby, small city bus station

Minimum lighting, adequate sound, minimum plumbing

Heat pump system

Average

Brick, block, concrete, good front and lobby, some trim

Finished interior, suspended ceiling, terrazzo lobby, small main terminal

Average lighting, good sound and plumbing, lounge

Warm and cool air (zoned)

Good

Brick, block, concrete, good decorative front and lobby

Vaulted ceilings, pavers, terrazzo, good air- or train-type terminal

Good lighting, sound systems and plumbing, food service

Hot and chilled water (zoned)

Very Good

Face brick, stone, terra cotta, ornamental entrance and lobby

Good finishes throughout, some extras, typical major terminal facility

Special lighting, good sound systems and plumbing, some extras

Complete HVAC.

Excellent

High-cost roof, large arched entries and domed skylights

Special finishes, acoustic design, high-cost lobby, concourse finishes

High-quality specialty lighting, best wiring throughout, good plumbing

Complete HVAC.

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Low-cost wood or stucco, very plain

Few partitions, very plain, minimum waiting and concession/ticket area

Minimum code, public address system

Package A.C.

Fair

Siding or stucco, small entrance

Drywall, acoustic tile, vinyl composition lobby, small city bus station

Minimum lighting, adequate sound, minimum plumbing

Heat pump system

Average

Stucco or siding, good front and lobby, some trim

Finished interior, suspended ceiling, terrazzo lobby, small main terminal

Average lighting, good sound and plumbing, lounge

Warm and cool air (zoned)

Good

Stucco, some brick or stone trim, decorative front and lobby

Vaulted ceilings, pavers, terrazzo, good air-or train-type terminal

Good lighting, sound systems and plumbing, food service

Hot and chilled water (zoned)

Very Good

Face brick or stone veneer, ornamental entrance and lobby

Good finishes throughout, some extras, typical major terminal facility

Special lighting, good sound systems and plumbing, some extras

Complete HVAC.

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Pole frame and truss, metal siding, low-cost finish and insulation

Few partitions, very plain, minimum waiting and concession/ticket area

Minimum code, public address system

Package A.C.

Fair

Metal panels on pole frame, finished interior, small entrance

Drywall, acoustic tile, vinyl composition lobby, small city bus station

Minimum lighting, adequate sound, minimum plumbing

Heat pump system

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Single wall, low-cost interior finish and insulation

Few partitions, very plain, minimum waiting and concession/ticket area

Minimum code, public address system

Package A.C.

Fair

Metal panels, finished interior, small entrance, masonry sound walls

Drywall, acoustic tile, vinyl composition lobby, small city bus station

Minimum lighting, adequate sound, minimum plumbing

Heat pump system

Average

Good metal panels, roof, front and lobby, some trim

Finished interior, suspended ceiling, terrazzo lobby, small main terminal

Average lighting, good sound and plumbing, lounge

Warm and cool air (zoned)