These light commercial buildings have semicircular (culvert) shape roofs that curve to the ground to form the sides. These buildings have many uses, such as general material, commodity or equipment storage and repair, and are generally lighter than typical warehouse buildings. Interior modifications can turn them into any one of several uses. The better qualities will have some built-in shop or workbench cabinetry and adequate lighting and plumbing.
Note: Exterior wall choices are not available for this occupancy.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 17 and 47.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
-- |
20 |
-- |
-- |
20 |
20 |
-- |
Average |
-- |
-- |
-- |
25 |
-- |
-- |
25 |
25 |
-- |
Good |
-- |
-- |
-- |
30 |
-- |
-- |
30 |
30 |
-- |
Excellent |
-- |
-- |
-- |
30 |
-- |
-- |
30 |
30 |
-- |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Arch-rib frame, siding, composition shingles |
Unfinished, cheap slab/asphalt |
Minimum electrical service |
None |
Average |
Arched frame, shingles and siding, windows, overhead door |
Unfinished, concrete or asphalt floor, some partitioning, cabinets |
Adequate lighting and water outlets |
None |
Good |
Good laminated arch, siding, shingles, pedestrian and overhead doors |
Small office or shop area, concrete floor, some extras |
Good lighting and outlets, water service, few fixtures |
Space heaters |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Light arch-rib frame, metal siding |
Unfinished, cheap slab/asphalt |
Minimum electrical service |
None |
Average |
Pre-engineered arched frame, metal siding, windows, overhead door |
Unfinished, concrete or asphalt floor, some partitioning, cabinets |
Adequate lighting and water outlets |
None |
Good |
Good laminated arch, metal siding, pedestrian and overhead doors |
Small office or shop area, concrete floor, some extras |
Good lighting and outlets, water service, few fixtures |
Space heaters |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Self-framing Quonset panels |
Unfinished, cheap slab/asphalt |
Minimum electrical service |
None |
Average |
Pre-engineered Quonset, metal siding, windows, overhead door |
Unfinished, concrete or asphalt floor, some partitioning, cabinets |
Adequate lighting and water outlets |
None |
Good |
Good self-framing Quonset panels, pedestrian and overhead doors |
Small office or shop area, concrete floor, some extras |
Good lighting and outlets, water service, few fixtures |
Space heaters |