Police stations are basically law enforcement facilities with a limited number of jail cells. Sallyport facilities commensurate with the quality are included.
The costs include jail hardware but do not include kitchen, laundry or recreational equipment.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 15 and 45.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
45 |
45 |
40 |
35 |
-- |
-- |
-- |
-- |
-- |
Average |
50 |
50 |
45 |
40 |
-- |
-- |
-- |
-- |
-- |
Good |
55 |
55 |
50 |
45 |
-- |
-- |
-- |
-- |
-- |
Excellent |
55 |
55 |
50 |
45 |
-- |
-- |
-- |
-- |
-- |
Class A (Fireproof Structural Steel Frame) and Class B (Reinforced Concrete Frame)
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Precast concrete, block, very plain |
Painted concrete, some plaster, acoustic tile, and asphalt tile, slab |
Adequate lighting & plumbing, some extras, holding cells |
Heat pump system |
Average |
Brick, precast concrete, good block, some trim |
Plaster or drywall, ceramic tile, acoustic tile, and asphalt tile, good concrete |
Good lighting, plumbing, security and sallyport, good holding facility |
Warm and cool air (zoned) |
Good |
Best block, concrete, masonry and glass, some ornamentation |
Plaster or drywall, ceramic tile, acoustic tile, carpet and asphalt tile |
Good lighting, plumbing, security for law enforcement center |
Warm and cool air (zoned) |
Excellent |
Best brick, stone, architectural concrete, good lobby |
Plaster, vinyl wall coverings, acoustic tile, terrazzo, vinyl tile, good detail |
Best lighting, plumbing and security, major command center |
Hot and chilled water (zoned) |
Class C (Masonry Bearing Walls)
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Block, tilt-up, very plain |
Unfinished walls and floors, low-cost ceilings and floors in public areas |
Minimum plumbing and lighting, minimum administrative and cells |
Forced air |
Average |
Block or brick, concrete, some ornamentation on front |
Painted walls, few partitions, some acoustic and vinyl composition, slab |
Adequate lighting & plumbing, some extras, holding cells |
Package A.C. |
Good |
Heavy stone or brick masonry, some ornamentation |
Plaster and acoustic tile, vinyl and ceramic floors, good slab |
Good lighting, plumbing, security and sallyport, good holding facility |
Heat pump system |
Excellent |
Face brick, stone, architectural concrete, glass, good lobby |
Plaster, paneling, carpet and terrazzo, suspended ceilings, best administrative |
Good lighting, plumbing, security for law enforcement center |
Warm and cool air (zoned) |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Wood frame or pipe columns, good stucco or siding with some trim |
Painted walls, acoustic tile or drywall ceilings, some asphalt tile, slab |
Adequate lighting & plumbing, some extras, holding cells |
Package A.C. |
Good |
Steel or Glulam frame and joists, brick veneer, glass, best stucco |
Plaster or drywall, acoustic tile, vinyl composition, carpet, good slab |
Good lighting, plumbing, security and sallyport, good holding facility |
Heat pump system |
Excellent |
Face brick or stone veneer, metal and glass, good lobby |
Plaster, paneling, carpet and terrazzo, suspended ceilings, best administrative |
Good lighting, plumbing, security for law enforcement center |
Warm and cool air (zoned) |