489 Jail, Police Station

Police stations are basically law enforcement facilities with a limited number of jail cells. Sallyport facilities commensurate with the quality are included.

The costs include jail hardware but do not include kitchen, laundry or recreational equipment.

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 15 and 45.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

45

45

40

35

--

--

--

--

--

Average

50

50

45

40

--

--

--

--

--

Good

55

55

50

45

--

--

--

--

--

Excellent

55

55

50

45

--

--

--

--

--

Quality Selection Guide:

Class A (Fireproof Structural Steel Frame) and Class B (Reinforced Concrete Frame)

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Precast concrete, block, very plain

Painted concrete, some plaster, acoustic tile, and asphalt tile, slab

Adequate lighting & plumbing, some extras, holding cells

Heat pump system

Average

Brick, precast concrete, good block, some trim

Plaster or drywall, ceramic tile, acoustic tile, and asphalt tile, good concrete

Good lighting, plumbing, security and sallyport, good holding facility

Warm and cool air (zoned)

Good

Best block, concrete, masonry and glass, some ornamentation

Plaster or drywall, ceramic tile, acoustic tile, carpet and asphalt tile

Good lighting, plumbing, security for law enforcement center

Warm and cool air (zoned)

Excellent

Best brick, stone, architectural concrete, good lobby

Plaster, vinyl wall coverings, acoustic tile, terrazzo, vinyl tile, good detail

Best lighting, plumbing and security, major command center

Hot and chilled water (zoned)

Class C (Masonry Bearing Walls)

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Block, tilt-up, very plain

Unfinished walls and floors, low-cost ceilings and floors in public areas

Minimum plumbing and lighting, minimum administrative and cells

Forced air

Average

Block or brick, concrete, some ornamentation on front

Painted walls, few partitions, some acoustic and vinyl composition, slab

Adequate lighting & plumbing, some extras, holding cells

Package A.C.

Good

Heavy stone or brick masonry, some ornamentation

Plaster and acoustic tile, vinyl and ceramic floors, good slab

Good lighting, plumbing, security and sallyport, good holding facility

Heat pump system

Excellent

Face brick, stone, architectural concrete, glass, good lobby

Plaster, paneling, carpet and terrazzo, suspended ceilings, best administrative

Good lighting, plumbing, security for law enforcement center

Warm and cool air (zoned)

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Wood frame or pipe columns, good stucco or siding with some trim

Painted walls, acoustic tile or drywall ceilings, some asphalt tile, slab

Adequate lighting & plumbing, some extras, holding cells

Package A.C.

Good

Steel or Glulam frame and joists, brick veneer, glass, best stucco

Plaster or drywall, acoustic tile, vinyl composition, carpet, good slab

Good lighting, plumbing, security and sallyport, good holding facility

Heat pump system

Excellent

Face brick or stone veneer, metal and glass, good lobby

Plaster, paneling, carpet and terrazzo, suspended ceilings, best administrative

Good lighting, plumbing, security for law enforcement center

Warm and cool air (zoned)