This occupancy includes the entire school facility that includes a mixture of classrooms, multipurpose buildings, administrative offices, etc. The schools may consist of one building or several separate buildings. This occupancy's emphasis is on trade and technical skills with a greater proportion of shops and laboratories.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 18 and 48.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
45 |
45 |
40 |
35 |
-- |
-- |
35 |
35 |
-- |
Average |
45 |
45 |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Good |
50 |
50 |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Excellent |
50 |
50 |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Class A (Fireproof Structural Steel Frame):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Brick, precast concrete, block, some trim |
Plaster or drywall, acoustic tile, some hardwood or vinyl composition |
Good lighting, many outlets, good plumbing |
Warm and cool air (zoned) |
Good |
Brick, concrete or metal panels, formed concrete |
Plaster or drywall, acoustic tile, carpet and vinyl, some sealed concrete |
Best fluorescent fixtures and outlets, good plumbing |
Hot and chilled water (zoned) |
Class B (Reinforced Concrete Frame):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Brick, precast concrete, block, some trim |
Plaster or drywall, acoustic tile, some hardwood or vinyl composition |
Good lighting, many outlets, good plumbing |
Warm and cool air (zoned) |
Good |
Brick, concrete or metal panels, formed concrete |
Plaster or drywall, acoustic tile, carpet and vinyl, some sealed concrete |
Best fluorescent fixtures and outlets, good plumbing |
Hot and chilled water (zoned) |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Brick, block, tilt-up panels, bearing walls, wood joists, little trim |
Painted walls, some ceiling and floor finish, sealed concrete |
Adequate lighting and outlets, minimum plumbing |
Forced air |
Average |
Steel frame or bearing walls, brick, block or concrete, some trim |
Painted walls, acoustic tile or drywall ceilings, some asphalt tile |
Good lighting, many outlets, adequate plumbing |
Package A.C. |
Good |
Steel columns, web or bar joists, ornamental block or face brick |
Plaster or drywall, acoustic tile, vinyl composition, carpet, good slab |
Good fluorescent fixtures and outlets, good plumbing |
Warm and cool air (zoned) |
Excellent |
Steel frame, face brick, metal panels, tile, some ornament |
Plaster, glazed finishes, enamel, carpet and vinyl, some sealed concrete |
Best lighting and wiring, good plumbing |
Hot and chilled water (zoned) |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Wood frame, stucco or siding, very plain |
Painted walls, some ceiling and floor finish, sealed concrete |
Adequate lighting and outlets, minimum plumbing |
Forced air |
Average |
Wood frame or pipe columns, good stucco or siding with some trim |
Painted walls, acoustic tile or drywall ceilings, some asphalt tile |
Good lighting, many outlets, adequate plumbing |
Package A.C. |
Good |
Steel or glulam frame and joists, brick veneer, glass, best stucco |
Plaster or drywall, acoustic tile, vinyl composition, carpet, good slab |
Good fluorescent fixtures and outlets, good plumbing |
Warm and cool air (zoned) |
Excellent |
Steel or wood frame, brick or stone veneer, metal and glass, ornamental |
Plaster, enamel, glazed or vinyl finishes, some carpet and vinyl |
Best lighting and wiring, good plumbing |
Hot and chilled water (zoned) |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Pole frame, metal siding, some interior finish, insulation |
Painted walls, some ceiling and floor finish, sealed concrete |
Adequate lighting and outlets, minimum plumbing |
Forced air |
Average |
Pole frame, good metal panels, finished inside, little trim |
Painted walls, acoustic tile or drywall ceiling, some asphalt tile |
Good lighting, many outlets, adequate plumbing |
Package A.C. |
Good |
Pole frame, best metal panels, some brick or stone trim |
Plaster or drywall, acoustic tile, vinyl composition, carpet, good slab |
Good fluorescent fixtures and outlets, good plumbing |
Warm and cool air (zoned) |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Pre-engineered, some finished interior, insulation |
Painted walls, some ceiling and floor finish, sealed concrete |
Adequate lighting and outlets, minimum plumbing |
Forced air |
Average |
Pre-engineered, sandwich panels, some ornamentation |
Painted walls, acoustic tile or drywall ceiling, some asphalt tile |
Good lighting, many outlets, adequate plumbing |
Package A.C. |
Good |
Pre-engineered, good sandwich panels, some brick or stone trim |
Plaster or drywall, acoustic tile, vinyl composition, carpet, good slab |
Good fluorescent fixtures and outlets, good plumbing |
Warm and cool air (zoned) |