487 Vocational School

This occupancy includes the entire school facility that includes a mixture of classrooms, multipurpose buildings, administrative offices, etc. The schools may consist of one building or several separate buildings. This occupancy's emphasis is on trade and technical skills with a greater proportion of shops and laboratories.

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 18 and 48.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

45

45

40

35

--

--

35

35

--

Average

45

45

45

40

--

--

40

40

--

Good

50

50

45

40

--

--

40

40

--

Excellent

50

50

45

40

--

--

40

40

--

Quality Selection Guide:

Class A (Fireproof Structural Steel Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Brick, precast concrete, block, some trim

Plaster or drywall, acoustic tile, some hardwood or vinyl composition

Good lighting, many outlets, good plumbing

Warm and cool air (zoned)

Good

Brick, concrete or metal panels, formed concrete

Plaster or drywall, acoustic tile, carpet and vinyl, some sealed concrete

Best fluorescent fixtures and outlets, good plumbing

Hot and chilled water (zoned)

Class B (Reinforced Concrete Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Brick, precast concrete, block, some trim

Plaster or drywall, acoustic tile, some hardwood or vinyl composition

Good lighting, many outlets, good plumbing

Warm and cool air (zoned)

Good

Brick, concrete or metal panels, formed concrete

Plaster or drywall, acoustic tile, carpet and vinyl, some sealed concrete

Best fluorescent fixtures and outlets, good plumbing

Hot and chilled water (zoned)

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick, block, tilt-up panels, bearing walls, wood joists, little trim

Painted walls, some ceiling and floor finish, sealed concrete

Adequate lighting and outlets, minimum plumbing

Forced air

Average

Steel frame or bearing walls, brick, block or concrete, some trim

Painted walls, acoustic tile or drywall ceilings, some asphalt tile

Good lighting, many outlets, adequate plumbing

Package A.C.

Good

Steel columns, web or bar joists, ornamental block or face brick

Plaster or drywall, acoustic tile, vinyl composition, carpet, good slab

Good fluorescent fixtures and outlets, good plumbing

Warm and cool air (zoned)

Excellent

Steel frame, face brick, metal panels, tile, some ornament

Plaster, glazed finishes, enamel, carpet and vinyl, some sealed concrete

Best lighting and wiring, good plumbing

Hot and chilled water (zoned)

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Wood frame, stucco or siding, very plain

Painted walls, some ceiling and floor finish, sealed concrete

Adequate lighting and outlets, minimum plumbing

Forced air

Average

Wood frame or pipe columns, good stucco or siding with some trim

Painted walls, acoustic tile or drywall ceilings, some asphalt tile

Good lighting, many outlets, adequate plumbing

Package A.C.

Good

Steel or glulam frame and joists, brick veneer, glass, best stucco

Plaster or drywall, acoustic tile, vinyl composition, carpet, good slab

Good fluorescent fixtures and outlets, good plumbing

Warm and cool air (zoned)

Excellent

Steel or wood frame, brick or stone veneer, metal and glass, ornamental

Plaster, enamel, glazed or vinyl finishes, some carpet and vinyl

Best lighting and wiring, good plumbing

Hot and chilled water (zoned)

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Pole frame, metal siding, some interior finish, insulation

Painted walls, some ceiling and floor finish, sealed concrete

Adequate lighting and outlets, minimum plumbing

Forced air

Average

Pole frame, good metal panels, finished inside, little trim

Painted walls, acoustic tile or drywall ceiling, some asphalt tile

Good lighting, many outlets, adequate plumbing

Package A.C.

Good

Pole frame, best metal panels, some brick or stone trim

Plaster or drywall, acoustic tile, vinyl composition, carpet, good slab

Good fluorescent fixtures and outlets, good plumbing

Warm and cool air (zoned)

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Pre-engineered, some finished interior, insulation

Painted walls, some ceiling and floor finish, sealed concrete

Adequate lighting and outlets, minimum plumbing

Forced air

Average

Pre-engineered, sandwich panels, some ornamentation

Painted walls, acoustic tile or drywall ceiling, some asphalt tile

Good lighting, many outlets, adequate plumbing

Package A.C.

Good

Pre-engineered, good sandwich panels, some brick or stone trim

Plaster or drywall, acoustic tile, vinyl composition, carpet, good slab

Good fluorescent fixtures and outlets, good plumbing

Warm and cool air (zoned)