Field houses are large gymnasium-type structures designed for indoor and outdoor sports and practice facilities. The better quality structures will include complete spectator and team facilities commensurate with the quality.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 18 and 48.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
40 |
40 |
35 |
30 |
-- |
-- |
30 |
30 |
-- |
Average |
45 |
45 |
40 |
35 |
-- |
-- |
35 |
35 |
-- |
Good |
45 |
45 |
40 |
35 |
-- |
-- |
35 |
35 |
-- |
Excellent |
50 |
50 |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Class A (Fireproof Structural Steel Frame): and Class B (Reinforced Concrete Frame):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Steel columns and girders, face brick, best ornamental block |
Intramural and competitive sports venues, good support facilities |
Good lighting and outlets, showers and restrooms |
Warm and cool air (zoned) |
Good |
Good frame, face brick, stone, concrete or metal panels, solar glass |
Good exhibition floor, varied sports and spectator facilities |
Good lighting and outlets, good plumbing, extra features |
Hot and chilled water (zoned) |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Light frame, block or tilt-up, very plain |
Low-cost finishes, minimal support facilities, synthetic flooring |
Minimum sports lighting & plumbing |
Space heaters |
Average |
Steel or glulam, trusses or girders, brick, block or tilt-up |
Multisport fields, some courts, co-recreation/sports activities |
Adequate lighting & plumbing, locker rooms |
Package A.C. |
Good |
Steel columns and girders, face brick, best ornamental block |
Intramural and competitive sports venues, good support facilities |
Good lighting and outlets, showers and restrooms |
Heat pump system |
Excellent |
Heavy frame, best masonry walls, spectator entrance and lobby |
Good exhibition floor, some arena finishes and spectator facilities |
Good lighting and outlets, good plumbing, extra features |
Warm and cool air (zoned) |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Light frame, stucco or siding, very plain |
Low-cost finishes, minimal support facilities, synthetic flooring |
Minimum sports lighting & plumbing |
Space heaters |
Average |
Heavy frame, trusses or girders, good stucco or siding, little trim |
Multisport fields, some courts co-recreation/sports activities |
Adequate lighting & plumbing, locker rooms |
Package A.C. |
Good |
Steel or glulam frame, trusses and girders, brick veneer, best stucco |
Intramural and competitive sports venues, good support facilities |
Good lighting and outlets, showers and restrooms |
Heat pump system |
Excellent |
Heavy frame, masonry veneer walls, spectator entrance and lobby |
Good exhibition floor, some arena finishes and spectator facilities |
Good lighting and outlets, good plumbing, extra features |
Warm and cool air (zoned) |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Pole frame, metal single wall, very plain |
Little or none, no dressing rooms or showers, practice field only |
Minimum lighting and restrooms |
Ventilation |
Low |
Pole frame, metal siding, partly finished interior, insulation |
Low-cost finishes, minimal support facilities, synthetic flooring |
Minimum sports lighting & plumbing |
Space heaters |
Average |
Pole frame, good metal panels, finished inside, little trim |
Multisport fields, some courts, co-recreation/sports activities |
Adequate lighting & plumbing, locker rooms |
Package A.C. |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Lowest |
Single wall, very plain |
Little or none, no dressing rooms or showers, practice field only |
Minimum lighting and restrooms |
Ventilation |
Low |
Pre-engineered, partly finished interior, some insulation |
Low-cost finishes, minimal support facilities, synthetic flooring |
Minimum sports lighting & plumbing |
Space heaters |
Average |
Pre-engineered, finished interior, insulation, little trim |
Multisport fields, some courts, co-recreation/sports activities |
Adequate lighting & plumbing, locker rooms |
Package A.C. |
Good |
Pre-engineered, good sandwich panels, some brick or stone trim |
Intramural and competitive sports venues, good support facilities |
Good lighting and outlets, showers and restrooms |
Heat pump system |