These light commercial three-walled buildings are designed for the storage and maintenance of equipment. Walls are usually either block or some type of metal or wood over the frame. Roof systems are either steel or wood, and the floors are concrete or asphalt. The better qualities will generally have good electrical circuits and/or water service.
For structures with extensive shop or office areas, use occupancy 528 (Service Repair Garage).
The following is not included in the costs: Service equipment.
For this occupancy, which may have one or more open sides, you should always enter the actual walled perimeter. If the shape option is used, the program calculates perimeter based on a three-sided structure.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 17 and 47.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
20 |
15 |
-- |
-- |
15 |
15 |
15 |
Average |
-- |
-- |
25 |
20 |
-- |
-- |
20 |
20 |
20 |
Good |
-- |
-- |
30 |
25 |
-- |
-- |
25 |
25 |
25 |
Excellent |
-- |
-- |
30 |
25 |
-- |
-- |
25 |
25 |
25 |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Open front, concrete block, light wood rafters |
Unfinished, concrete or asphalt floor, some cabinets, work area |
Adequate electrical and water service and outlets |
Space heaters |
Good |
Open front, block or low- cost brick, wood rafters |
Unfinished concrete floor, shop area and cabinets |
Good lighting and outlets, adequate plumbing |
Space heaters |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Open front, exposed frame, siding or stucco |
Unfinished, concrete or asphalt floor, some cabinets, work area |
Adequate electrical and water service and outlets |
Space heaters |
Good |
Open front, light frame and rafters, siding or stucco |
Unfinished concrete floor, shop area and cabinets |
Good lighting and outlets, adequate plumbing |
Space heaters |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Open front, enameled siding on wood pole frame |
Unfinished, concrete or asphalt floor, some cabinets, work area |
Adequate electrical and water service and outlets |
Space heaters |
Good |
Open front, good metal and pole frame |
Unfinished concrete floor, shop area and cabinets |
Good lighting and outlets, adequate plumbing |
Space heaters |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Open front, enameled siding on steel frame |
Unfinished, concrete or asphalt floor, some cabinets, work area |
Adequate electrical and water service and outlets |
Space heaters |
Good |
Open front, good metal and steel frame |
Unfinished concrete floor, shop area and cabinets |
Good lighting and outlets, adequate plumbing |
Space heaters |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Open front, enameled siding on steel slant frame |
Unfinished, concrete or asphalt floor, some cabinets, work area |
Adequate electrical and water service and outlets |
Space heaters |
Good |
Open front, good metal and steel slant frame |
Unfinished concrete floor, shop area and cabinets |
Good lighting and outlets, adequate plumbing |
Space heaters |