416 Indoor Tennis Club

These are shell type structures that include tennis court facilities. The cost of individual facilities can vary greatly depending on the type of structure and its appointments, including the extent of the lounge, refreshment, exercise, shower and spectator areas. Costs are given for the entire facility including suitable office and gathering areas.

Lower cost facilities are generally constructed with rigid steel or wood frame and an exterior cover of either wood or steel siding. These facilities have minimum lighting and plumbing and no dressing rooms or showers. Clear heights typically vary between 20 and 28 feet.

Average quality enclosed courts use either steel sandwich panels or masonry exterior walls and include dressing room and shower facilities. Clear heights typically vary between 24 and 32 feet.

The best qualities include high cost lighting and fixtures, lounge areas, snack bar facilities, a sales area where equipment can be sold, showers, dressing rooms and saunas. Clear heights vary between 30 and 35 feet.

The following are not included in the costs: Lockers, furnishings and exercise or kitchen equipment.

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 16 and 46.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

--

--

35

30

--

--

30

30

--

Average

--

--

40

35

--

--

35

35

--

Good

--

--

45

40

--

--

40

40

--

Excellent

--

--

45

40

--

--

40

40

--

Quality Selection Guide:

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Block or tilt-up

Little or none, no dressing rooms

Minimum lighting & plumbing

Space heaters

Average

Brick or block, concrete panels, some ornamentation

Drywall, concrete courts, snack bar area, exercise facilities

Adequate lighting, plumbing, showers, add for pool or spa

Forced air

Good

Brick or concrete, good entrance

Plaster or drywall, carpeting, good lounge and court areas, gym

Good sports lighting, restrooms, sauna, shower and locker rooms

Package A.C.

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Stucco or siding, very plain

Little or none, no dressing rooms

Minimum lighting & plumbing

Space heaters

Average

Good stucco or siding, some brick or stone trim

Drywall, concrete courts, snack bar area, exercise facilities

Adequate lighting, plumbing, showers, add for pool or spa

Forced air

Good

Brick veneer, best siding or stucco, trim, good entrance

Plaster or drywall, carpeting, good lounge and court areas, gym

Good sports lighting, restrooms, sauna, shower and locker rooms

Package A.C.

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Pole frame, metal single wall, very plain

No dressing rooms or showers, few facilities

Minimum lighting and restrooms

Space heaters

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Single wall, very plain

Little or none, no dressing rooms

Minimum lighting & plumbing

Space heaters

Average

Good metal panels and roof, some interior finish, trim

Drywall, concrete courts, snack bar area, exercise facilities

Adequate lighting, plumbing, showers, add for pool or spa

Forced air

Good

Insulated metal sandwich panels, steel frame, good entrance

Plaster or drywall, carpeting, good lounge and court areas, gym

Good sports lighting, restrooms, sauna, shower and locker rooms

Package A.C.