These are shell type structures that include tennis court facilities. The cost of individual facilities can vary greatly depending on the type of structure and its appointments, including the extent of the lounge, refreshment, exercise, shower and spectator areas. Costs are given for the entire facility including suitable office and gathering areas.
Lower cost facilities are generally constructed with rigid steel or wood frame and an exterior cover of either wood or steel siding. These facilities have minimum lighting and plumbing and no dressing rooms or showers. Clear heights typically vary between 20 and 28 feet.
Average quality enclosed courts use either steel sandwich panels or masonry exterior walls and include dressing room and shower facilities. Clear heights typically vary between 24 and 32 feet.
The best qualities include high cost lighting and fixtures, lounge areas, snack bar facilities, a sales area where equipment can be sold, showers, dressing rooms and saunas. Clear heights vary between 30 and 35 feet.
The following are not included in the costs: Lockers, furnishings and exercise or kitchen equipment.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 16 and 46.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
35 |
30 |
-- |
-- |
30 |
30 |
-- |
Average |
-- |
-- |
40 |
35 |
-- |
-- |
35 |
35 |
-- |
Good |
-- |
-- |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Excellent |
-- |
-- |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Block or tilt-up |
Little or none, no dressing rooms |
Minimum lighting & plumbing |
Space heaters |
Average |
Brick or block, concrete panels, some ornamentation |
Drywall, concrete courts, snack bar area, exercise facilities |
Adequate lighting, plumbing, showers, add for pool or spa |
Forced air |
Good |
Brick or concrete, good entrance |
Plaster or drywall, carpeting, good lounge and court areas, gym |
Good sports lighting, restrooms, sauna, shower and locker rooms |
Package A.C. |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Stucco or siding, very plain |
Little or none, no dressing rooms |
Minimum lighting & plumbing |
Space heaters |
Average |
Good stucco or siding, some brick or stone trim |
Drywall, concrete courts, snack bar area, exercise facilities |
Adequate lighting, plumbing, showers, add for pool or spa |
Forced air |
Good |
Brick veneer, best siding or stucco, trim, good entrance |
Plaster or drywall, carpeting, good lounge and court areas, gym |
Good sports lighting, restrooms, sauna, shower and locker rooms |
Package A.C. |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Pole frame, metal single wall, very plain |
No dressing rooms or showers, few facilities |
Minimum lighting and restrooms |
Space heaters |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Single wall, very plain |
Little or none, no dressing rooms |
Minimum lighting & plumbing |
Space heaters |
Average |
Good metal panels and roof, some interior finish, trim |
Drywall, concrete courts, snack bar area, exercise facilities |
Adequate lighting, plumbing, showers, add for pool or spa |
Forced air |
Good |
Insulated metal sandwich panels, steel frame, good entrance |
Plaster or drywall, carpeting, good lounge and court areas, gym |
Good sports lighting, restrooms, sauna, shower and locker rooms |
Package A.C. |