These structures are designed for the medical and surgical care and treatment of small animals. Floor finishes are resilient covering. Wall finishes, either plaster or drywall, are plain. Good quality facilities also have some lab and x-ray areas. Individual cubicles or rooms within the structure include adequate lighting and plumbing.
The following are not included in the costs: X-ray equipment, cages, runs or open shelters.
Availability of Elevators by Area for this occupancy: Yes
Marshall Valuation Service sections: 17 and 47.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
40 |
40 |
35 |
30 |
-- |
-- |
30 |
30 |
-- |
Average |
45 |
45 |
40 |
35 |
-- |
-- |
35 |
35 |
-- |
Good |
45 |
45 |
40 |
35 |
-- |
-- |
35 |
35 |
-- |
Excellent |
50 |
50 |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Class A (Fireproof Structural Steel Frame) and Class B: Reinforced Concrete Frame
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Brick, precast panels, some trim |
Plaster or drywall, vinyl, laboratory and X-ray facilities |
Good lighting & plumbing, power outlets (see Page 26) |
Hot and chilled water (zoned) |
Class C (Masonry Bearing Walls)
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Block or tilt-up, very plain |
Drywall, some asphalt tile floor |
Minimum lighting & plumbing |
Space heaters |
Average |
Brick, partially finished interior, some trim |
Plaster or drywall, vinyl composition |
Adequate lighting, fluoroscope outlets, adequate plumbing |
Forced air |
Good |
Face brick, ornamental block, good trim and fenestration |
Plaster or drywall, vinyl, good lab and X-ray facilities |
Good lighting & plumbing, power outlets |
Package A.C. |
Excellent |
Face brick, block or concrete, good entrance and trim |
Plaster, ceramic, vinyl and carpet finishes, indoor exercise facilities |
Good lighting & plumbing, lab, diagnostic and treatment facilities |
Warm and cool air (zoned) |
Class D (Wood or Steel Framed Exterior Walls)
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Stucco or siding, finished interior |
Drywall, some asphalt tile floor |
Minimum lighting & plumbing |
Space heaters |
Average |
Stucco or siding, brick trim or low cost brick veneer |
Plaster or drywall, vinyl composition |
Adequate lighting, fluoroscope outlets, adequate plumbing |
Forced air |
Good |
Good brick veneer, trim and fenestration |
Plaster or drywall, vinyl, good laboratory and X-ray facilities |
Good lighting & plumbing, power outlets |
Package A.C. |
Excellent |
Face brick or stone veneer, best siding, good entrance and trim |
Plaster, ceramic, vinyl and carpet finishes, indoor exercise facilities |
Good lighting & plumbing, lab, diagnostic and treatment facilities |
Warm and cool air (zoned) |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Pole frame, metal single wall, very plain |
Drywall, some asphalt tile floor |
Minimum lighting & plumbing |
Space heaters |
Class S (Metal Frame and Walls)
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Metal on light frame, very plain |
Drywall, some asphalt tile floor |
Minimum lighting & plumbing |
Space heaters |
Average |
Insulated sandwich panels or metal with finished interior |
Drywall, vinyl composition |
Adequate lighting, fluoroscope outlets, adequate plumbing |
Forced air |