376 Science Building (College)

Science buildings include areas for lectures, demonstrations, audiovisual presentations, laboratory work and study and some administrative and stage areas. Typically, there is also an area designated for storage of materials and equipment. The laboratories have both AC and DC variable voltage and plumbing in the work areas.

Since science buildings have higher requirements for heating, cooling and ventilation, use component 617 (Complete HVAC) for HVAC costs.

The following are not included in the costs: Lab equipment.

Availability of Elevators by Area for this occupancy: No

Marshall Valuation Service sections: 18 and 48.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

45

45

40

35

--

--

35

35

--

Average

50

50

45

40

--

--

40

40

--

Good

60

60

50

45

--

--

45

45

--

Excellent

60

60

55

50

--

--

50

50

--

Quality Selection Guide:

Class A (Fireproof Structural Steel Frame): and Class B (Reinforced Concrete Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick, precast concrete, block, little trim

Low cost finishes, acoustic tile, VCT, plain classrooms and offices

Minimum lab lighting & plumbing, few extras

Complete HVAC.

Average

Brick, concrete or metal panels, formed concrete

Plaster or drywall, acoustic tile, VCT, carpet, good teaching and support

Adequate lighting & plumbing, some extra features

Complete HVAC.

Good

Face brick, stone, concrete or metal panels, solar glass

Plaster or drywall, acoustic tile, carpet and vinyl, good teaching and research

Good fluorescent fixtures, good lab stations and plumbing

Complete HVAC.

Excellent

Stone, best brick, metal and glass, highly ornamental

Plaster, glazed finishes, enamel, tile, many workstations, support facilities

Best lab plumbing and lighting, many extras

Complete HVAC.

Class C (Masonry Bearing Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Brick, block, tilt-up panels, bearing walls, wood joists, little trim

Painted walls, acoustic tile or drywall, VCT, plain classrooms and offices

Minimum lab lighting & plumbing

Complete HVAC.

Average

Steel frame or bearing walls, brick, block, or concrete, some trim

Plaster or drywall, acoustic tile, VCT, adequate teaching, support facilities

Adequate lighting, plumbing and workstations

Complete HVAC.

Good

Steel columns, web or bar joists, ornamental block or face brick

Plaster or drywall, acoustic tile, vinyl or carpet, teaching, good research

Good fluorescent fixtures, lab stations and plumbing

Complete HVAC.

Excellent

Steel frame, face brick, metal panels, tile, highly ornamental

Plaster, glazed finishes, enamel, tile, carpet, vinyl, good support facilities

Best lab stations and plumbing, good lighting and outlets

Complete HVAC.

Class D (Wood or Steel Framed Exterior Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Wood frame, stucco or siding, little ornamentation

Drywall, acoustic tile, vinyl composition, plain classrooms and offices

Minimum lab lighting & plumbing

Complete HVAC.

Average

Wood frame or pipe columns, good stucco or siding with some trim

Plaster or drywall, acoustic tile, vinyl composition or hardwood

Adequate lighting, plumbing and workstations

Complete HVAC.

Good

Steel or glulam frame and joists, brick veneer, glass, best stucco

Plaster or drywall, acoustic tile, vinyl or carpet, teaching and research

Good fluorescent fixtures, lab stations and plumbing

Complete HVAC.

Excellent

Steel or wood frame, brick or stone veneer, metal and glass, ornamental

Plaster, glazed finishes, enamel, tile, carpet, vinyl, good support facilities

Best lab stations and plumbing, good lighting and outlets

Complete HVAC.

Class P (Pole Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Pole frame, good metal panels, finished inside, little trim

Drywall, acoustic tile, vinyl composition, plain classrooms and offices

Minimum lab lighting & plumbing

Complete HVAC.

Average

Pole frame, insulated metal panels, some ornamentation

Plaster or drywall, acoustic tile, VCT, adequate teaching, support facilities

Adequate lighting, plumbing and workstations

Complete HVAC.

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Pre-engineered, finished interior, insulation

Drywall, acoustic tile, vinyl composition, plain classrooms and offices

Minimum lab lighting & plumbing

Complete HVAC.

Average

Pre-engineered, sandwich panels, some trim

Plaster or drywall, acoustic tile, VCT, adequate teaching, support facilities

Adequate lighting, plumbing and workstations

Complete HVAC.

Good

Pre-engineered, good sandwich panels, some brick or stone

Plaster or drywall, acoustic tile, vinyl or carpet, teaching and research

Good fluorescent fixtures, lab stations and plumbing

Complete HVAC.