Science buildings include areas for lectures, demonstrations, audiovisual presentations, laboratory work and study and some administrative and stage areas. Typically, there is also an area designated for storage of materials and equipment. The laboratories have both AC and DC variable voltage and plumbing in the work areas.
Since science buildings have higher requirements for heating, cooling and ventilation, use component 617 (Complete HVAC) for HVAC costs.
The following are not included in the costs: Lab equipment.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 18 and 48.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
45 |
45 |
40 |
35 |
-- |
-- |
35 |
35 |
-- |
Average |
50 |
50 |
45 |
40 |
-- |
-- |
40 |
40 |
-- |
Good |
60 |
60 |
50 |
45 |
-- |
-- |
45 |
45 |
-- |
Excellent |
60 |
60 |
55 |
50 |
-- |
-- |
50 |
50 |
-- |
Class A (Fireproof Structural Steel Frame): and Class B (Reinforced Concrete Frame):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Brick, precast concrete, block, little trim |
Low cost finishes, acoustic tile, VCT, plain classrooms and offices |
Minimum lab lighting & plumbing, few extras |
Complete HVAC. |
Average |
Brick, concrete or metal panels, formed concrete |
Plaster or drywall, acoustic tile, VCT, carpet, good teaching and support |
Adequate lighting & plumbing, some extra features |
Complete HVAC. |
Good |
Face brick, stone, concrete or metal panels, solar glass |
Plaster or drywall, acoustic tile, carpet and vinyl, good teaching and research |
Good fluorescent fixtures, good lab stations and plumbing |
Complete HVAC. |
Excellent |
Stone, best brick, metal and glass, highly ornamental |
Plaster, glazed finishes, enamel, tile, many workstations, support facilities |
Best lab plumbing and lighting, many extras |
Complete HVAC. |
Class C (Masonry Bearing Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Brick, block, tilt-up panels, bearing walls, wood joists, little trim |
Painted walls, acoustic tile or drywall, VCT, plain classrooms and offices |
Minimum lab lighting & plumbing |
Complete HVAC. |
Average |
Steel frame or bearing walls, brick, block, or concrete, some trim |
Plaster or drywall, acoustic tile, VCT, adequate teaching, support facilities |
Adequate lighting, plumbing and workstations |
Complete HVAC. |
Good |
Steel columns, web or bar joists, ornamental block or face brick |
Plaster or drywall, acoustic tile, vinyl or carpet, teaching, good research |
Good fluorescent fixtures, lab stations and plumbing |
Complete HVAC. |
Excellent |
Steel frame, face brick, metal panels, tile, highly ornamental |
Plaster, glazed finishes, enamel, tile, carpet, vinyl, good support facilities |
Best lab stations and plumbing, good lighting and outlets |
Complete HVAC. |
Class D (Wood or Steel Framed Exterior Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Wood frame, stucco or siding, little ornamentation |
Drywall, acoustic tile, vinyl composition, plain classrooms and offices |
Minimum lab lighting & plumbing |
Complete HVAC. |
Average |
Wood frame or pipe columns, good stucco or siding with some trim |
Plaster or drywall, acoustic tile, vinyl composition or hardwood |
Adequate lighting, plumbing and workstations |
Complete HVAC. |
Good |
Steel or glulam frame and joists, brick veneer, glass, best stucco |
Plaster or drywall, acoustic tile, vinyl or carpet, teaching and research |
Good fluorescent fixtures, lab stations and plumbing |
Complete HVAC. |
Excellent |
Steel or wood frame, brick or stone veneer, metal and glass, ornamental |
Plaster, glazed finishes, enamel, tile, carpet, vinyl, good support facilities |
Best lab stations and plumbing, good lighting and outlets |
Complete HVAC. |
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Pole frame, good metal panels, finished inside, little trim |
Drywall, acoustic tile, vinyl composition, plain classrooms and offices |
Minimum lab lighting & plumbing |
Complete HVAC. |
Average |
Pole frame, insulated metal panels, some ornamentation |
Plaster or drywall, acoustic tile, VCT, adequate teaching, support facilities |
Adequate lighting, plumbing and workstations |
Complete HVAC. |
Class S (Metal Frame and Walls):
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Pre-engineered, finished interior, insulation |
Drywall, acoustic tile, vinyl composition, plain classrooms and offices |
Minimum lab lighting & plumbing |
Complete HVAC. |
Average |
Pre-engineered, sandwich panels, some trim |
Plaster or drywall, acoustic tile, VCT, adequate teaching, support facilities |
Adequate lighting, plumbing and workstations |
Complete HVAC. |
Good |
Pre-engineered, good sandwich panels, some brick or stone |
Plaster or drywall, acoustic tile, vinyl or carpet, teaching and research |
Good fluorescent fixtures, lab stations and plumbing |
Complete HVAC. |