345 Parking Structure

Built above grade, these structures are designed for live load storage of autos. They commonly have either no exterior walls or partial exterior walls and are usually Class A or B buildings, and in some cases Class S.

While the lower quality structures do not have office area, the better qualities have some small office and service areas. There is low-level lighting and adequate plumbing for office restrooms and service areas.

The quality of these structures can be influenced by their design characteristics. Ramp designs vary from separate and exclusive ramps, which separate the travel and the parking/unparking operations, to continuous sloping floor or adjacent ramp, which have both the travel and parking operations integrated within the same space. The determination of the type of ramp used is based on the site's shape and dimensions and the parking demand characteristics. The costs are based on the number of stories where there is always one more parking level (rooftop) than stories.

The following are not included in the costs: Pedestrian bridges, signs and parking or service equipment.

Availability of Elevators by Area for this occupancy: Yes

Marshall Valuation Service sections: 14 and 44.

Typical Lives:

 

 

 

 

 

Class

 

 

 

 

Quality

A

B

C

D

H

M

P

S

W

Low

40

40

--

--

--

--

--

35

--

Average

40

40

--

--

--

--

--

35

--

Good

45

45

--

--

--

--

--

40

--

Excellent

45

45

--

--

--

--

--

40

--

Quality Selection Guide:

Class A (Fireproof Structural Steel Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Average

Partial walls, brick, block, concrete, little trim

Unfinished, small office and service area

Low-level lighting, drains, minimum restroom for office

None

Good

Partial walls, brick or concrete, ornamentation

Unfinished, except good office and service area

Reading-level lighting, restrooms and service plumbing

None

Class B (Reinforced Concrete Frame):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Low

Low parapets, precast frame and floors, minimum finish

Unfinished, minimum extras

Minimum lighting & plumbing

None

Average

Partial walls, brick, block, concrete, plain finish

Unfinished, small office and service area

Low-level lighting, drains, minimum restroom for office

None

Good

Partial walls, brick or concrete, ornamentation

Unfinished, except good office and service area

Reading-level lighting, restrooms and service plumbing

None

Class S (Metal Frame and Walls):

Quality

Exterior Walls

Interior Finish

Mechanicals

HVAC

Lowest

Demountable type, exposed steel frame, cable rails

Unfinished, no extras

Minimum lighting, drains only

None

Low

Demountable type, exposed steel frame

Unfinished, some masonry shear walls, minimum extras

Low-level lighting, drains, minimum personnel plumbing

None