These are buildings designed for urgent care or emergency first aid and medical treatment. Typically, they do not have facilities for surgery, although the better qualities may have some small surgical capabilities. They do generally have some office space.
Floor coverings are either ceramic tile or some type of resilient floor finish throughout the structure. Lighting and plumbing are adequate for emergency first aid use.
The following are not included in the costs: Medical equipment, surgery facilities and emergency power facilities.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 15 and 45.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
45 |
45 |
35 |
30 |
-- |
-- |
-- |
30 |
-- |
Average |
45 |
45 |
35 |
30 |
-- |
-- |
-- |
30 |
-- |
Good |
50 |
50 |
40 |
35 |
-- |
-- |
-- |
35 |
-- |
Excellent |
50 |
50 |
45 |
40 |
-- |
-- |
-- |
40 |
-- |
Class A (Fireproof Structural Steel Frame) and Class B: Reinforced Concrete Frame:
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Brick, precast panels, metal and glass, little trim |
Drywall or plaster, acoustic tile, vinyl composition, some ceramic pavers |
Adequate lighting & plumbing for emergency first aid and care |
Warm and cool air (zoned) |
Good |
Brick, metal and glass, some ornamentation |
Plaster or drywall, good enamel or vinyl walls, ceramic, vinyl, rubber tile |
Good lighting & plumbing, first aid and overnight care |
Warm and cool air (zoned) |
Class C (Masonry Bearing Walls)
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Brick, block, tilt-up, very plain finish |
Drywall or plaster, acoustic tile, vinyl composition tile |
Adequate lighting & plumbing for emergency first aid |
Forced air |
Good |
Brick or block, good fenestration, some trim |
Drywall or plaster, acoustic tile, vinyl composition, some ceramic pavers |
Good lighting & plumbing, first aid and overnight care |
Package A.C. |
Class D (Wood or Steel Framed Exterior Walls)
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Stucco or siding, very plain |
Drywall, acoustic tile, vinyl composition |
Adequate lighting & plumbing |
Forced air |
Good |
Brick veneer, or best stucco or siding |
Drywall or plaster, acoustic tile, ceramic tile, vinyl composition |
Good lighting & plumbing, first aid and overnight care |
Package A.C. |
Class S (Metal Frame and Walls)
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Metal siding, finished interior |
Drywall, acoustic tile, vinyl composition tile |
Adequate lighting & plumbing for emergency first aid |
Forced air |