These structures are small vandal resistant and weatherproof, prefabricated storage type sheds. Costs include a concrete plank or metal deck floor, minimum electrical and no plumbing.
Note: Exterior wall choices are not available for this occupancy.
The following are not included in the costs: Any process equipment, power wiring or panels.
Availability of Elevators by Area for this occupancy: No
Marshall Valuation Service sections: 17 and 47.
|
|
|
|
|
Class |
|
|
|
|
Quality |
A |
B |
C |
D |
H |
M |
P |
S |
W |
Low |
-- |
-- |
20 |
-- |
-- |
-- |
-- |
15 |
-- |
Average |
-- |
-- |
25 |
-- |
-- |
-- |
-- |
20 |
-- |
Good |
-- |
-- |
25 |
-- |
-- |
-- |
-- |
20 |
-- |
Excellent |
-- |
-- |
30 |
-- |
-- |
-- |
-- |
25 |
-- |
Class C (Masonry Bearing Walls)
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Average |
Modular concrete panels, security weather tight door |
Unfinished walls, concrete plank floor |
Few open fixtures, no plumbing |
None |
Good |
Heavy concrete wall and roof panels, vandal-resistant doors |
Sealed walls and heavy concrete plank floor |
Rigid conduit, spark-proof fixtures, no plumbing |
None |
Class S (Metal Frame and Walls)
Quality |
Exterior Walls |
Interior Finish |
Mechanicals |
HVAC |
Low |
Metal panels and sheathing on steel frame, security door |
Unfinished interior, steel floor |
One or two lights and outlets, no plumbing |
None |
Average |
Good steel panels on steel frame, security door |
Sealed steel floor, some wainscot |
Few open fixtures, no plumbing |
None |
Good |
Heavy steel panels on steel studs, heavy doors |
Heavy/steel floor, sealed walls, vandal resistant |
Rigid conduit, spark-proof fixtures, no plumbing |
None |