CCE Concrete, Siding/Stucco

A concrete foundation for Class D buildings, where a perimeter stem or heavy-grade beam carries all of the load.

Included in Cost

Excavation, trenching, forming, reinforcing, concrete and backfill.

Not Included in Cost

Column footings. For column footings supporting a roof or floor load use one of the following components:

CD (Concrete Column Footing, Wood Column)

CDA (Concrete Column Footing, Wood Column, Light Pole Frame)

CE (Concrete Column Footing, Steel Column)

CAE (Concrete, Siding/Stucco)

CF (Concrete Column Footing, Concrete Column)

Quality Selection

Consider the following when selecting a quality:

Load supported: The greater the load, the higher the quality.

Size and shape: The higher the ratio of the perimeter to floor area, the higher the quality.

Load-bearing capacity of the soil: The lower the capacity, the higher the quality.

Topography: Stepped foundations require a higher quality.

Climate: The deeper the frost line, the higher the quality.

Entry Information

Enter the following for this component:

Length (Feet)

Construction System

Foundation

Typical Use

Class D buildings with Siding or Stucco exterior walls